Zalman ZM600-HP Plus [3/5] Specifications

Zalman ZM600-HP Plus [3/5] Specifications
22
3. Specications
1) ZM500-HP PLUS Electrical & Physical Specications
2) ZM500-HP PLUS Output Power Cable Specications
AC Input Range
Voltage 100 ~ 240VAC ZM500-HP PLUS
Frequency 50 ~ 60
V
out
Output Load Rating Combined
Combined
Power
AC Input Current
115VAC 8A I
min
I
max
I
peak
230VAC 4A +3.3V 0.5A 24A
130W
500W
PFC Type Active PFC +5V 0.1A 24A
Power Factor MAX 99% +12V1 0.1A 18A 20A
432W
Inrush Current Limit
(@ Cold start at 25)
115VAC 55A +12V2 0.1A 18A 20A
230VAC 110A -12V 0.0A 0.5A
21W
Efciency MAX 88% @ 230VAC, Typical load +5VSB 0.1A 3A 3.5A
DC Output Voltag
e
Regulation
V
out
Stable Range
At
Full
Load
Ambient Temperature
+3.3VDC ±5% +3.14 ~ +3.47V Operation 10 ~ 40
+5VDC ±5% +4.75 ~ +5.25V Stored -20 ~ 80
+12V1DC ±5% +11.4 ~ +12.6V Ambient Humidity
+12V2DC ±5% +11.4 ~ +12.6V Operation 5 ~ 95%RH
-12VDC ±10% -10.8 ~ -13.0V Stored 5 ~ 95%RH
+5VSB ±5% +4.75 ~ +5.25V Dimensions 165(L) × 150(W) × 86(H)
DC Output Ripple
& Noise
V
out
Standard Range
At
Full
Load
Weight 2.79(Full Package)
+3.3VDC
50mV Protection Features
+5VDC 50mV Over-Voltage Protection (OVP)
+12V1DC 120mV Over-Current Protection(OCP)
+12V2DC 120mV Under-Voltage Protection(UVP)
-12VDC 120mV Short-Circuit Protection(SCP)
+5VSB 50mV Over -Temperature Protection(OTP)
Скачать