Zalman ZM600-HP Plus [4/5] Zm600 hp plus electrical physical specifications

Zalman ZM600-HP Plus [4/5] Zm600 hp plus electrical physical specifications
33
4) ZM600-HP PLUS Output Power Cable Specications
AC Input Range
Voltage 100 ~ 240VAC ZM600-HP PLUS
Frequency 50 ~ 60
V
out
Output Load Rating Combined
Combined
Power
AC Input Current
115VAC 10A I
min
I
max
I
peak
230VAC 6A +3.3V 0.5A 24A
140W
600W
PFC Type Active PFC +5V 0.1A 24A
Power Factor MAX 99% +12V1 0.1A 18A 20A
576W
Inrush Current Limit
(@ Cold start at 25)
115VAC 80A +12V2 0.1A 18A 20A
230VAC 150A +12V3 0.1A 18A 20A
Efciency MAX 88% @ 230VAC, Typical load +12V4 0.1A 18A 20A
DC Output Voltag
e
Regulation
V
out
Stable Range
At
Full
Load
-12V 0.0A 0.5A
21W
+3.3VDC ±5% +3.14 ~ +3.47V +5VSB 0.1A 3A 3.5A
+5VDC ±5% +4.75 ~ +5.25V Ambient Temperature
+12V1DC ±5% +11.4 ~ +12.6V Operation 10 ~ 40
+12V2DC ±5% +11.4 ~ +12.6V Stored -20 ~ 80
+12V3DC ±5% +11.4 ~ +12.6V Ambient Humidity
+12V4DC ±5% +11.4 ~ +12.6V Operation 5 ~ 95%RH
-12VDC ±10% -10.8 ~ -13.0V Stored 5 ~ 95%RH
+5VSB ±5% +4.75 ~ +5.25V Dimensions
DC Output Ripple
& Noise
V
out
Standard Range
At
Full
Load
165(L) × 150(W) × 86(H)
+3.3VDC 50mV Weight
+5VDC 50mV 2.8(Full Package)
+12V1DC 120mV Protection Features
+12V2DC 120mV Over-Voltage Protection(OVC)
+12V3DC 120mV Over-Current Protection(OCP)
+12V4DC 120mV Under-Voltage Protection(UVP)
-12VDC 120mV Short-Circuit Protection(SCP)
+5VSB 50mV Over -Temperature Protection(OTP)
3) ZM600-HP PLUS Electrical & Physical Specications
Скачать