Buffalo TS3400D1204 [173/181] Status

Buffalo TS3400D1204 [173/181] Status
172
E10 UPS Running
Off Battery
The TeraStation is running on the UPS
battery due to a power outage. The system
will now be shut down safely.
Check that power is being supplied to the
UPS, and if there are no problems, turn on
the TeraStation.
I10 System Is
Overheating
A rise in the system temperature may have
exceeded the allowable safety value.
Move the TeraStation to a cool location. Do
not place objects in the area around the
TeraStation.
E11 Fan Failure An error occurred in the fan speed.
Check that no foreign objects or dust are
clogging the fan. If any foreign objects or
dust are found, use a pair of tweezers, air
duster, or other tool to remove them. If the
error is displayed again, contact Buffalo
technical support for assistance.
E12 Cooling
Failure
A rise in the system temperature may have
exceeded the allowable safety value.
Do not place objects in the area around the
TeraStation. Also, move the TeraStation to a
cool location.
E14 Can't Mount
Array x
RAID array x cannot be mounted. Run the RAID array disk check in Settings.
E16 Drive x Not
Found
Unable to find drive x.
Hard drive x may be disconnected or may
have failed. After shutting down, reinstall the
hard drive.
E22 Can't Mount
Drive x
Mounting of hard drive x failed.
Format the hard drive. After formatting, if the
error still appears after rebooting, replace
the hard drive. If the error is displayed
again, contact Buffalo technical support for
assistance.
E27 Lost Failover
Target
Unable to find the backup TeraStation.
In the main TeraStation's settings, navigate
to Backup - Failover to reconfigure the
backup TeraStation for failover.
E30 Replace Drive
x
An error occurred, so hard drive x was
removed from the RAID array.
Replace hard drive x.
Status
After you change settings or format a hard drive, the current status is displayed on the LCD.
LCD Message Description Corrective Action
I11 Bad Sectors on
Drive x
The bad sectors in hard drive x may
have reached a dangerous level.
Replace hard drive x.
I12 Degraded Mode Operating in degraded mode. -
I13 Formatting
Array x...
Formatting RAID array x. -
I14 Checking Array
x…
Checking RAID array x. -
I15 Scanning Array
x Data...
Examining the error status of RAID
array x.
-
I16 Creating Array
x...
Creating RAID array x. -
I17 Resyncing Array
x...
Resynchronizing RAID array x. -
I18 Rebuilding
Array x...
Rebuilding RAID array x. -