Suzuki GS1000 (1980) Инструкция по эксплуатации онлайн [173/477] 114749

Содержание

ELECTRICAL SYSTEM Commutator Inspect the commutator surface for wear high mica burns or grooving To smooth the sur face sand it down with sandpaper as shown in armature coil Undercut the mica to the depth specified Fig 11 19 Standard undercut Starter motor specifications The motor is mounted on top of the crankcase behind the cylinder block and drives the engine s crankshaft by a series of gears and a one way clutch which is mounted on the alter nator rotor The motor either DENSO or MITSUBA is made and is made to the follow ing electrical specifications Item Voltage Current Torque Speed No load data 11 volts 50 amperes under Limit on undercut 0 6 mm 0 023 in 0 2 mm 0 008 in Locked rotor data 5 5 volts 280 amperes under 0 35 kg m over 4 500 rpm over INSPECTION OF COMPONENTS Carbon brushes When the brushes are worn the motor will be unable to produce sufficient current and the engine will be difficult to crank over In order to prevent this periodically inspect the length of the brushes replacing those which are too short Brush length specification 11 8 Standard Service limit 12 13 mm 0 47 0 51 in 6 mm 0 24 in Armature coil Using a circuit tester check the coil for open and ground by putting probe pins on each com mutator segment and rotor core to test for ground and on any two segments at various places to test for open with the brushes lifted off the commutator surface If the coil is found to be open circuited or grounded replace the armature Continued use of such an armature is will cause the starter motor to suddenly fail

Скачать