Check the reading as corrected to 20 C with Fig 11 31 to determine the recharging time in hours by constant current charging at a charg ing rate of 3 amperes which is a tenth of the capacity of the present battery Be careful not to permit the electrolyte temperature to exceed 45 C 113 F at any time during the recharging operation Interrupt the operation as necessary to let the electrolyte cool down The battery is properly recharged if any three of the following four conditions are met Fig 11 31 Recharging has been carried out to the specification stated in Fig 11 32 s graph Electrolyte S G rose to 1 260 or higher and has remained there for at least one hour The battery terminal voltage rose to 15 16 volts or higher and has remained there for at least one hour Gaseous bubbles are being released in every cell Fig 11 32 Limit the charging current to 14 amperes Limit the electrolyte temperature to 55 C 132 F Recharge with the battery detached from the motorcycle Never attempt to quick charge the battery in place Exercise all common sense precautions on battery recharging Operate the charger in a manner consistent with the directions prescribed for the charger 11 12