Fubag ti 2600 [29/70] Page28

Содержание

Fubag Operator s manual www fubag ru 5 Visually inspect the spark plug Discard it if the insulator is cracked or chipped Clean the spark plug with a wire brush if it is to be reused 6 Measure the plug gap with a feeler gauge The gap should be 0 6 0 7 mm Correct as necessary by carefully bending the side electrode 7 Install the spark plug carefully by hand to avoid cross threading 8 After a new spark plug has been seated by hand it should be tightened 1 2 turn with a wrench to compress its washer If a used plug is being reinstalled it should only require 1 8 to 1 4 turn afte being seated 9 Reinstall the spark plug cap on the spark plug securely 10 Reinstall the spark plug maintenance cover 0 6 0 7 MM A CAUTION The spark plug must be securely tightened An improperly tightened plug can become very hot and possibly damage the generator Never use a spark plug with an improper heat range Never use a spark plug without damping resistance or it will cause no AC output 4 Spark arrester maintenance A WARNING If the generator has been running the muffler will be very hot Allow it to cool before proceeding 1 Remove the four screws and remove the muffler protector Screw 28