Freggia HA631VW [16/48] Instructions for the installer

16
INSTRUCTIONS FOR THE INSTALLER
• ELECTRIC CONNECTION
The connection to the electric grid must be carried out by quali ed personnel and in conformity with the regulations
in force.
The voltage of the electric system must correspond to the value indicated in the label under the appliance. Make
sure that the electric system is provided with an e ective ground connction in compliance with the regulations and
provisions of the law. Grounding is compulsory.
This device must be at a suitable opening distance from the contacts in order to allow the entire disconnection in case
of overvoltage category III, in accordance with installation rules.
GAS TRANSFORMATIONS AND ADJUSTMENTS
• REPLACING THE NOZZLES
If the equipment is adjusted for a type of gas that is di erent from the one available, it is necessary to replace the
burner nozzles.
The choice of the nozzles to replace must be made according to the table of the “technical characteristics as enclosed.
Act as follows:
Remove the racks and burners.
By means of a straight spanner L, unscrew the nozzle U ( g.8) and substitute it with the corresponding one.
Tighten the nozzle strongly.
• ADJUSTING THE BURNERS
The lowest  ame point must always be properly adjusted and the  ame must remain on even if there is an abrupt shift
from the maximum to the minimum position.
If this is not so, it is necessary to adjust the lowest  ame point as follows:
start the burner up
turn the tap up to the minimum position (small  ame)
remove the knob from the tap rod
introduce a  at-tip screwdriver in the hole F of the tap ( g. 9-9/A) and turn the by-pass screw up to a proper
adjustment of the lowest  ame point.
As regards G30 gas burners, the by-pass screw must be tightened completely.
MAINTENANCE
REPLACING THE POWER SUPPLY CABLE
If the power supply cable should be replaced, it is necessary to use a cable with a section of 3x0.75mm2, type H05VV-F
or H05RR-F, complying with the regulations in force for the hob with gas burners. For the hob with electric plates and
power under 1500W 3x1mm2 power cable should be used.
The connection to the terminal board must be e ected as shown in  g. 10 - 10/A:
brown cable L (phase)
blue cable N (neutral)
green-yellow cable (ground)
The manufacturing  rm refuses all responsibility for any possible imprecision in this booklet, due to misprints or clerical
errors. It reserves the right to make all the changes that it will consider necessary in its own products, without e ecting
the essential characteristics of functionality and safety.