Smeg SER60SGH3 — guidelines for Safe Installation of Gas Hobs and Ventilation [8/18]
![Smeg SER60SGH3 [8/18] Ventilation of rooms](/views2/1015816/page8/bg8.png)
Instructions for the installer
28
Use a pressure regulator and make the connection to the tank according
to the provisions of standards regulations in force. Make sure that feed
pressure conforms to the levels shown in the table in paragraph “5.2
Regulation for LPG”.
4.2 Ventilation of rooms
The hob may be installed only in rooms with permanent ventilation, as
required by standards regulations in force. The room in which the hob is
installed must have sufficient air flow to satisfy the requirements of
normal gas combustion and of necessary air exchange in the room. The
air intakes, protected by screens, must be appropriately sized
(regulations in force) and placed so as not to be blocked in any way.
The room where the oven is installed should be suitably ventilated to
avoid overheating or excess humidity produced by cooking, and in the
case of lengthy use a window should be opened or the speed of any
ventilators should be increased.
4.3 Discharge of combustion products
Discharge of combustion products must be guaranteed by means of
hoods connected to a natural draught flue with certain efficiency, or by
means of forced aspiration.
An efficient aspiration system requires careful planning by a specialist
capable of installing it, respecting the positions and distances prescribed
by standards. After installation, the installer must issue a certificate of
conformity.
Содержание
- Electrical connection ______________________________ 26 p.1
- Instructions for safe and proper use_______________ 22 p.1
- Cleaning and maintenance ___________________________ 37 p.1
- Adaptation to different types of gas _______________ 29 p.1
- Using the hob ________________________________________ 34 p.1
- Positioning of hob ___________________________________ 24 p.1
- Gas connection______________________________________ 27 p.1
- Final operations_____________________________________ 32 p.1
- Introduction p.2
- Instructions for safe and proper use p.2
- The manufacturer declines all responsibility for damage to persons or things caused by non observance of the above prescriptions or by interference with any part of the appliance or by the use of non original spares p.3
- Introduction p.3
- Instructions for the installer p.4
- Positioning of hob p.4
- Attachment to support structure p.4
- Instructions for the installer p.5
- Instructions for the installer p.6
- Electrical connection p.6
- Connection to lpg p.7
- Instructions for the installer p.7
- Gas connection p.7
- Ventilation of rooms p.8
- Instructions for the installer p.8
- Discharge of combustion products p.8
- Removing the hob p.9
- Instructions for the installer p.9
- Adaptation to different types of gas p.9
- Regulation for lpg p.10
- Loosen screw a and push support b all the way use a double head wrench to remove nozzle c and assemble the suitable one following the instructions indicated in the reference charts with respect to the type of gas to use the screwing torque of the nozzle should never exceed 3 nm reposition support b so that nozzle c is covered perfectly move the venturi tube d to regulate the air flow until distance x is reached indicated in the chart in paragraph 5 regulation of primary air and then secure the tube by means of screw a after the regulations have been carried out restore the seals with sealing wax or equivalent material p.10
- Instructions for the installer p.10
- The hob has been inspected for g20 2h natural gas at a pressure of 20 mbar to allow the unit to work with this type of gas perform the same operations described in paragraph 5 regulation for lpg but choose the nozzles and regulate the primary air for natural gas as shown in the following table and in paragraph 5 regulation of primary air after the regulations have been carried out restore the seals with sealing wax or equivalent material p.11
- Regulation of primary air p.11
- Regulation for natural gas p.11
- Referred to distance x in mm p.11
- Instructions for the installer p.11
- To identify the burners on your hob refer to the drawings in point 6 arrangement of burners on hob p.11
- Regulation of minimum for natural gas p.12
- Regulation of minimum for lpg p.12
- Instructions for the installer p.12
- Final operations p.12
- Lubrication of gas taps p.13
- Instructions for the installer p.13
- Arrangement of burners on hob p.13
- After a while the gas tap may become hard to turn or lock if this happens it has to be cleaned inside and re greased this must be done by a qualified technician p.13
- Using the hob p.14
- Instructions for the user p.14
- Ignition of the burners p.14
- Practical advice for using the burners p.15
- Instructions for the user p.15
- Electric elements p.15
- Diameter of containers p.15
- Using a griddle plate p.15
- Turning on electric elements p.15
- Using the electric elements p.16
- Instructions for the user p.16
- Regular daily cleaning of the hob p.17
- Instructions for the user p.17
- Food stains or residues p.17
- Cleaning and maintenance p.17
- Cleaning p.17
- The cover p.18
- Instructions for the user p.18
- Ignition plugs and safety devices p.18
- Cleaning of cooking hob components p.18
Похожие устройства
-
Smeg PV175S-1Руководство по эксплуатации -
Smeg PV164N-1Руководство по эксплуатации -
Smeg PGF96Руководство по эксплуатации -
Smeg PV175CBРуководство по эксплуатации -
Smeg PV175BРуководство по эксплуатации -
Smeg PV164CNРуководство по эксплуатации -
Smeg PV164CBРуководство по эксплуатации -
Smeg PV164B-1Руководство по эксплуатации -
Smeg PVS750Руководство по эксплуатации -
Smeg SER60SGH3Руководство по эксплуатации -
Smeg SE70SGH-5Руководство по эксплуатации -
Smeg PGF32GРуководство по эксплуатации
Follow essential guidelines for installing gas hobs, ensuring proper ventilation and combustion product discharge. Ensure compliance with safety standards for optimal performance.