Netis ST3326(ST-3302) [117/118] Link status indicator don t shows normal link error

Netis ST3326(ST-3302) [117/118] Link status indicator don t shows normal link error
117
Chapter16:FAQ
16.1 Link status indicator don't shows normal (Link-Error)
View the link end is connected to a PC card or other Ethernet interface;
Check that, the joint at ends of the cable is rust or damaged;
Use WEB to check this port's communication configuration (duplex, speed), to make sure
configuration the same as another end of link's.
Caution: If both ends' duplex and speed are forced to be set, one link's configuration have to
match with another's, otherwise it is unable to establish a connection.
16.2Link status indicator show normal
but can't communication
When this happens, please do as follows:
Use WEB form (Show in "Port state search") to check whether the port is stopped or not, if the
port was stopped, use a WEB form (Show in "Port configuration") to open the port;
Use WEB form to check whether the port is in the isolated VLAN or not, compared with other
ports ; Ports' communication can only be accessed, when they are in the same VLAN.
16.3 Can't login to manage switch
Please do as follows to check the switch:
Check whether the switch is power on or not;
Check for link failures; Use "PING" to check switch's response; if no response, check whether the
IP address configuration of switch and PC is correct or not; If that, you can determine the cause
of the problem, according to the feedback information of HTTPconnection.
Check the IP address setting
Please do as follows to check the switch:
Check whether the PCs IP address, subnet mask and default gateway is your expectation
Setting or not: Please input "ipconfig" in Windows command to check the PC's IP address
configurations.
Check whether the switch IP address ,subnet mask and default gateway is your expectation
Setting or not
Check whether the switch IP address is occupied by another equipment or not.
Check the login account
When login via WEB form, if switch continuously request user to enter account and password,
this maybe remind that the account don't exist or password invalid.
16.4 Switch start-up failure

Содержание