Powerman AVS 10000P [22/28] Installation and connection

Содержание

Installation and connection 1 The voltage stabilizer Switchion ON 2 Indicators of Uin And Uout 3 Status indicators 4 Increase of time delay 5 Electric mains connection 6 Connection of Grounding 7 Automatic safety fuse 8 Load Connection Warning Total power of connected load should not exceed the capacity of the voltage stabilizer If electric network is made in conformity with EC standards then 500VA 2000VA AVR do not require additional grounding Make sure that your main socket is connected to ground For connection use electric wires providing passage of maximum electric current for the given model see Specifications and reliability of contact connections In case of difficulty in selection of wires or connection of grounding by your own please call an electrician 1 Make sure that the stabilizer does not have mechanical damages 2 Perform grounding of the casing of the voltage stabilizer by connecting grounding wire to corresponding outlet 6 3 Plug in the voltage stabilizer to 220 VAC electric mains 5 4 Switch OFF increase of time delay 4 5 Switch ON the voltage stabilizer 1 After the unit is connected to mains the remaining time delay sec is immediately displayed at voltage display When delay is over the display show mains voltage Uin and load voltage Uout 6 With the hep of voltmeters make sure that the input and the output voltages are available 2 We recommend to check the input mains voltage level connection of high power consuming load in situation of low input voltage might cause AVS overload see Fig 3 7 Switch OFF the voltage stabilizer 1 8 Connect the load 8 9 Switch ON the voltage stabilizer 1 10 If necessary switch ON the increase of time delay 4 WWW POWERMAN RU