Zyxel P-791R v2 Рекомендации по настройке онлайн [14/98] 154425
![Zyxel P-791R v2 Рекомендации по настройке онлайн [14/98] 154425](/views2/1169426/page14/bge.png)
P-791R v2 Support Notes
Make sure the P-791R v2 is connected to the power adapter, the power
adapter is plugged into a power outlet and the power switch is at the ON
position.
8. How to debug while DSL LED is off?
Check the connection between the P-791R v2's DSL port and the wall socket
or remote devices. If you use the back to back application, check the service
type and the Standard Mode in both P-791R v2s.
9. How do I verify my PC's IP address assigned by the P-791R v2?
Make sure you have the P-791R v2 powered on and then turn on your PC.
After the PC starts, select " Run..." from the windows "Start" menu. Enter
"cmd" and click OK.You may check IP of your PC with “ipconfig”. Verify your
cabling if the IP address box shows "0.0.0.0".
10. What is Traffic Shaping?
Traffic Shaping is a feature in the P-791R v2. It allocates the bandwidth to
WAN dynamically and aims at boosting the efficiency of the bandwidth. If there
are serveral VCs in the P-791R v2 but only one VC activated at one time, the
P-791R v2 allocates all the Bandwidth to the VC and the VC gets full
bandwidth. If another VCs are avtivated later, the bandwidth is yield to other
VCs after ward.
11. What do the parameters (PCR, SCR, MBS) mean?
Traffic shaping parameters (PCR, SCR, MBS) can be set in Menu 4 and Menu
11.6 and is valid for both incoming and outgoing direction since G.shdsl is
symmetric.
Peak Cell Rate(PCR): The maximum bandwidth allocated to this connection.
The VC connection throughput is limited by PCR.
Sustainable Cell Rate(SCR): The least guaranteed bandwidth of a VC.
When there are multi-VCs on the same line, the VC throughput is guaranteed
by SCR.
Maximum Burst Size(MBS): The amount of cells transmitted through this
VC at the Peak Cell Rate before yielding to other VCs. Total bandwidth of the
line is dedicated to single VC if there is only one VC on the line. However, as
the other VC asking the bandwidth, the MBS defines the maximum number of
cells transmitted via this VC with Peak Cell rate before yielding to other VCs.
The P-791R v2 holds the parameters for shaping the traffic among its virtual
channels. If you do not need traffic shaping, please set SCR = 0, MBS = 0 and
14
All contents copyright © 2007 ZyXEL Communications Corporation.
Содержание
- G shdsl bis router 1
- P 791r v2 1
- Zynos faq 5
- Product faq 12
- Dsl faq 19
- Application notes 21
- General application notes 21
- Key settings 25
- Option description 25
- Lan wan packet trace 65
- Support tool 65
- Downloading using tftp 70
- Firmware configurations uploading and 70
- Downloading using ftp 73
- Firmware configurations uploading and 73
- Ci command reference 76
- Ppp numbers 77
- Reference 77
- Port numbers 90
- Protocol numbers 95
Похожие устройства
- Zyxel P-791R v2 Технические характеристики
- Zyxel P-791R v2 Сертификат
- HP pavilion 15-p203ur, l1s78ea Инструкция по эксплуатации
- HP pavilion 15-p205ur, l1s80ea Инструкция по эксплуатации
- HP pavilion 15-p206ur, l1s82ea Инструкция по эксплуатации
- Zyxel P-793H v2 Инструкция по эксплуатации
- Zyxel P-793H v2 Инструкция по установке
- Zyxel P-793H v2 Технические характеристики
- HP pavilion 15-p207ur, l1s84ea Инструкция по эксплуатации
- Zyxel P-792H v2 Инструкция по эксплуатации
- Zyxel P-792H v2 Инструкция по установке
- Zyxel P-792H v2 Технические характеристики
- HP pavilion 15-p208ur, l1s86ea Инструкция по эксплуатации
- Zyxel P-792H v2 Рекомендации по настройке
- HP pavilion 15-p209ur, l1s88ea Инструкция по эксплуатации
- HP pavilion 15-p210ur, l1s90ea Инструкция по эксплуатации
- HP pavilion 15-p211ur, l1s92ea Инструкция по эксплуатации
- HP pavilion 15-p214ur, l2v57ea Инструкция по эксплуатации
- HP pavilion 15-p217ur, l4h17ea Инструкция по эксплуатации
- HP pavilion 15-p250ur, l1t04ea Инструкция по эксплуатации
Скачать
Случайные обсуждения