Zyxel P-791R v2 [70/98] Firmware configurations uploading and

Zyxel P-791R v2 [70/98] Firmware configurations uploading and
P-791R v2 Support Notes
2. Firmware/Configurations Uploading and
Downloading using TFTP
Using TFTP client software
Upload/download ZyNOS via LAN
Upload/download P-791R v2 configurations via LAN
(1) Using TFTP to upload/download ZyNOS via LAN
Step 1: TELNET to your P-791R v2 first before running the TFTP software
Step 2: Type the CI command 'sys stdio 0' to disable console idle timeout
in Command Line Interface (CLI)
Step 3: Run the TFTP client software
Step 4: Enter the IP address of the P-791R v2
Step 5: To upload the firmware, please save the remote file as 'ras' to
P-791R v2. After the transfer is complete, the P-791R v2 will
program the upgraded firmware into FLASH ROM and reboot itself.
Example:
The 192.168.1.1 is the IP address of the P-791R v2. The local file is the source
file of the ZyNOS firmware that is available in your hard disk. The remote file is
the file name that will be saved in P-791R v2. Check the port number 69 and
512-Octet blocks for TFTP. Check 'Binary' mode for file transfering.
(2) Using TFTP to upload/download SMT configurations via LAN
Step 1: TELNET to your P-791R v2 first before running the TFTP software
70
All contents copyright © 2007 ZyXEL Communications Corporation.

Похожие устройства