Initial Setup
EN
P Lay the Template on the ground at the entrance to the Narrow
Pass:
) The
arrow points towards the entrance to the
Narrow Pass, in the direction of the Sub-Zone.
) Insert by hand (half-way in) 7 pegs into the 7 holes
numbered
1
7
.
P Lift the Template up so the pegs are left loosely stuck in the
ground.
P Lay the Perimeter Wire through the four right-side pegs numbered
1
4
) Hold the wire around each peg
1
,
2
,
3
,
4
while
driving the peg all the way into the ground.
) Leave pegs 5 – 7 standing half-way out. They will be
connected to the wire later.
P Continue laying the Perimeter Wire through the pass towards
the Sub-Zone:
) Straight line at a minimum distance of 45 cm (1.5 ft.) from
the pass right side edge.
) Pause at the end of the Pass in order to set the other end
of the Narrow Pass.
P There should be a 40 cm (1.3 ft.) distance between the Sub-
Zone Perimeter Wire and the pass exit.
P Turn the Template and lay it on the ground at the entrance to
the Sub-Zone:
) The
arrow points towards the Sub-Zone.
) Insert by hand (half-way in) 7 pegs into the 7 holes
numbered 1 – 7.
P Lift the Template up so the pegs are left loosely stuck in the
ground.
P Lay the Perimeter Wire through the three right side pegs
numbered 1 – 3
) Hold the wire around each peg 1, 2, 3 while driving the
peg all the way into the ground.
B
1
START
END
2
4
1
3
5
6
7
2
4
1
3
5
6
7
B
1
START
END
2
4
1
3
5
6
7
2
4
1
3
5
6
7
1
B
1
B
1
END
START
2
4
1
3
5
6
7
2
4
1
3
5
6
7
1
B
1
Lay the Template
Turn the Template and lay it on the ground
Insert
1
7
pegs
Insert 1 – 7
pegs
Lay Perimeter Wire
through
1
4
pegs
Lay Perimeter Wire through
1 – 3
pegs
Starting the Sub-Zone Passage setup
Main Zone
Main Zone
Main Zone
Main Zone
Main Zone
Sub-Zone
Sub-Zone
Sub-Zone
Sub-Zone
Sub-Zone