Lenovo x3650 m5, 5462d2g [20/54] X 2 inch drives are supported on storage dense models only models without the system x3650 m5 2 odd lcd light path bay fc a5fy the first configuration in figure 5

Lenovo x3650 m5, 5462c2g [20/54] X 2 inch drives are supported on storage dense models only models without the system x3650 m5 2 odd lcd light path bay fc a5fy the first configuration in figure 5
2.5-inch SAS/SATA
hot-swap (rear)
4 2x M1215
(2+2 drives)
Factory installed:
2x System x3650 M5 Rear 2x 2.5" HDD Kit
(Independent RAID) (FC A5GH)
Field upgrade for 2.5-inch HS drive models:
2x System x3650 M5 Rear 2x 2.5" HDD Kit
(PN 00FK658)
3.5-inch SAS/SATA
hot-swap (rear)
2 1x RAID or HBA
(12+2 drives)***
Factory installed:
1x System x3650 M5 Rear 2x 3.5" HDD Kit
(Cascaded) (FC A5GL)
Field upgrade for 3.5-inch HS drive models:
1x System x3650 M5 Rear 2x 3.5" HDD Kit
(PN 00FK659)
1x M1215
(2 drives)
Factory installed:
1x System x3650 M5 Rear 2x 3.5" HDD Kit
(Independent RAID) (FC A5GK)
Field upgrade for 3.5-inch HS drive models:
1x System x3650 M5 Rear 2x 3.5" HDD Kit
(PN 00FK659)
Drive bay type Drive
bay qty
Storage controller* Drive kits required
* In the Storage controller column, RAID or HBA means that any combination of the M1215, M5210, and N2215 storage
controllers is supported up to a maximum quantity listed; the numbers in brackets (x+y+z) specify the number of drives
connected to each of the storage controllers.
# Each PCIe SSD Extender Adapter (PN 00ML997) provides connectivity for up to two PCIe SSDs, and each adapter occupies
a PCIe slot. For factory configured models, two PCIe SSD Extender Adapters (FC AS95) must be included in the configuration.
For field upgrades, the PCIe SSD Upgrade Kit (PN 00FK677) includes two PCIe SSD Extenders.
** Requires a storage configuration with 8x or 16x 2.5-inch SAS/SATA hot-swap drive bays (one of the first three storage
configurations listed in Table 8). For 16x 2.5-inch hot-swap drive bay configurations, the internal optical drive is not supported.
*** Two drives in the 2x 3.5-inch Rear HDD Kit are connected to the SAS expander on the 12-drive backplane, that is, to the
same storage controller as 12 drives on the front.
The following additional rules apply to the storage configurations:
24x 2.5-inch drives are supported on storage dense models only (models without the System x3650
M5 2.5" ODD/LCD Light Path Bay, FC A5FY; the first configuration in Figure 5).
2x 2.5-inch rear drives are supported on 2.5-inch and 3.5-inch hot-swap drive bay models.
If the 2x 3.5-inch Rear HDD Kit is installed and connected to a dedicated controller, the 2x
2.5-inch Rear HDD Kit cannot be installed.
4x 2.5-inch rear drives are supported on 2.5-inch hot swap drive bay models only.
2x 3.5-inch rear drives are supported on 3.5-inch hot-swap drive bay models only.
With 8x 3.5-inch HS drive bay models, the 2x 3.5-inch Rear HDD Kit is connected to a
dedicated M1215 controller, and the 2x 2.5-inch Rear HDD Kit cannot be installed.
With 12x 3.5-inch HS drive bay models, the 2x 3.5-inch Rear HDD Kit can be connected to a
dedicated M1215 controller or SAS expander on the 12-drive backplane. If the 2x 3.5-inch
Rear HDD Kit is connected to a dedicated M1215 controller, the 2x 2.5-inch Rear HDD Kit
cannot be installed. If the 2x 3.5-inch Rear HDD Kit is connected to a SAS expander, the 2x
2.5-inch Rear HDD Kit can be installed.
Both 2.5-inch and 3.5-inch Rear HDD Kits are not supported on Simple Swap models.
NVMe PCIe SSDs are supported on 8x or 16x 2.5-inch SAS/SATA hot-swap drive bay models only.
For 16x 2.5-inch SAS/SATA hot-swap drive bay configurations, the internal optical drive is not
supported in the configurations with NVMe PCIe SSDs. Rear HDD kits are not supported in the
configurations with NVMe PCIe SSDs.
Lenovo System x3650 M5 20