Oregon Scientific wmr300 [11/15] Backlight
![Oregon Scientific wmr300 [11/15] Backlight](/views2/1176365/page11/bgb.png)
11
EN
OR
• Touch anywhere on the screen (except tool bar / area) to confirm
and exit.
To enable / disable alarms:
1. Press desired area to activate.
2. Press to display set HI / LO alarm.
3. Press to turn alarm on or off.
NOTE
- - indicates alarm is not set / disabled.
NOTE
Clock alarm sound is different from weather alarms to allow for easy
differentiation by user.
To silence any alarm:
• Press anywhere on the touch panel.
OR
• The alarm automatically turns off after 2 minutes.
NOTE
When alarm is on, the channel of triggered alarm will be flashed and alarm
sound lasts for 2 minutes.
BACKLIGHT
Press anywhere on the touch panel to activate the backlight for 8 seconds.
OR
If the main unit is powered by power adapter, switch the
LIGHT to ON in the main
unit compartment. The light will be on until you switch it OFF.
NOTE
You need to take off the battery compartment cover to do switching.
RESET
Main unit:
Press RESET to return to the default settings.
NOTE
You need to take off the battery compartment
cover to do switching.
Transmitter box:
Press RESET to remove the record of the calibrated
wind direction.
MAINTAINANCE
Each sensor of this kit has a durable plastic casing that should retain its luster for
many years. It is better to do regular maintenance to keep the sensors with high
accuracy every half year. Do cleaning the casing only with a soft cloth slightly
dampened with water or a mild soap. Please use screw drivers or wrench to take
some parts off if necessary.
Electrical storms can sometimes cause power surges harmful to electronic
equipment. For your own safety, take caution when using the main unit or doing
maintenance during storms.
TO MAINTAIN THE THERMO/HYGRO SENSOR
1. Remove the rain collector from the rain gauge.
2.
Unscrew the three type B screws from the rain gauge.
3. Unscrew the three screws from the bottom of
the thermo/hygro sensor casing.
4. Clean the casing excluding the one with sensor
by water, and then remove the dust around the
sensor carefully.
5. Install all the parts until they are entirely dried.
NOTE
If the temperature and humidity readings are
still strange and inaccurate, you need to consider
replacing this sensor, please contacting our customer service for the details.
TROUBLE SHOOTING
Problem Symptom Remedy
Barometer Strange readings Check altitude setting on the main unit.
Wind sensor No updates of the
wind direction
Check the wind vane.
Display dashes on
main unit
1. Check the connections.
2. Check the channel setting.
3. Check the pairing successful or not.
Rain sensor No readings 1. Check the cable tie on the tipping
bucket to be cut away or not.
2. Check the balance indicator.
3. Check the plastic filter in rain collector.
4. Check the connections.
Strange readings 1. Check the plastic filter in the rain collector.
2. Check the balance indicator.
Tem p/h ygr o
sensor
Display dashes 1. Check the connections.
2. Check the pairing.
3. Check the channel setting.
No outdoor temp/
hygro readings
1. Check the rechargeable battery in
transmitter box.
2. Check the power adapter connection
and main unit batteries status.
3. Do maintenance for the sensor.
Calendar Strange date /
month
1. Change language.
2. Check the calendar setting.
Clock Cannot adjust
clock
Disable radio-controlled clock.
Cannot
auto-synchronize
1. Check batteries status.
2. Reset the main unit.
3. Manually activate radio controlled clock.
Sunrise/
Sunset
Strange readings 1. Set longitude/latitude.
2. Check the daylight saving time setting.
Transmitter
box
LED light(s) do not
flash
1. Check the switch.
2. Check the polarity of the
rechargeable battery.
3. Check the connection of the solar panel.
Sensors
pairing
Time is too long 1. Adjust the antennas to be parallel.
2. Reset the pairing switch (switch off
then on again).
PRECAUTIONS
• Do not subject the unit to excessive force, shock, dust, temperature or humidity.
• Do not cover the ventilation holes with any items such as newspapers, curtains etc.
• Do not immerse the unit in water. If you spill liquid over it, dry it immediately
with a soft, lint-free cloth.
• Do not clean the unit with abrasive or corrosive materials.
• Do not tamper with the unit’s internal components. This invalidates the warranty.
• Only use fresh batteries. Do not mix new and old batteries.
• Images shown in this manual may differ from the actual display.
•
When disposing of this product, ensure it is collected separately for special treatment.
• Placement of this product on certain types of wood may result in damage to its
finish for which Oregon Scientific will not be responsible. Consult the furniture
manufacturer’s care instructions for information.
• The contents of this manual may not be reproduced without the permission of
the manufacturer.
• Do not dispose old batteries as unsorted municipal waste. Collection of such
waste separately for special treatment is necessary.
• Please note that some units are equipped with a battery safety strip. Remove
the strip from the battery compartment before first use.
NOTE
The technical specifications for this product and the contents of the user
manual are subject to change without notice.
RESET KEY
Содержание
- Contents 1
- Display unit 1
- Introduction 1
- Model wmr300 wmr300a 1
- Packaging contents 1
- Rain gauge 1
- Solar transmitter 1
- Ultra precision professional weather system 1
- User manual 1
- 12 13 14 15 4
- Bar chart 4
- Clock alarm weather forecast moon phase 4
- Dew point heat index wind chill 4
- Outdoor temperature humidity 4
- Sunrise sunset 4
- Wind speed wind direction 4
- Barometer 5
- Cable connections 5
- Installation 5
- Rainfall 5
- Set up rain sensor thermo hygro sensor 5
- Set up transmitter box 5
- Set up wind sensor 5
- Main unit batteries installation 7
- Manually set clock 7
- Pairing sensors remove sensors 7
- Alarm clock 8
- Clock reception 8
- Dewpoint heat index wind chill 8
- Moon phase 8
- Temperature and humidity 8
- Weather forecast 8
- Accumulated rainfall 9
- Bar chart 9
- Barometric pressure 9
- Direction calibration 9
- Rainfall 9
- Sunrise sunset 9
- Wind speed direction 9
- Data log 10
- Hourly records 10
- Max min of today monthly records 10
- Memory 10
- Backlight 11
- Maintainance 11
- Precautions 11
- To maintain the thermo hygro sensor 11
- Trouble shooting 11
- Indoor barometer 12
- Indoor relative humidity 12
- Indoor temperature 12
- Main unit 12
- Outdoor temperature humidity unit relative temperature 12
- Radio controlled atomic clock 12
- Rain gauge 12
- Relative humidity 12
- Solar rf transmitter box 12
- Specifications 12
- Wind sensor unit 12
- About oregon scientific 13
- Declaration of conformity 13
- Eu declaration of conformity 13
- Fcc statement 13
Похожие устройства
- Oregon Scientific cw101 Инструкция по эксплуатации
- Oregon Scientific bar218hg Инструкция по эксплуатации
- Oregon Scientific rar500n Инструкция по эксплуатации
- Oregon Scientific bar801 Инструкция по эксплуатации
- Oregon Scientific rrm222p Инструкция по эксплуатации
- Oregon Scientific bar223p Инструкция по эксплуатации
- ТРИД РК 112-1В3Р-485 Инструкция по эксплуатации
- Oregon Scientific tw396 Инструкция по эксплуатации
- Oregon Scientific rar213hg Инструкция по эксплуатации
- Oregon Scientific ws907 Инструкция по эксплуатации
- Oregon Scientific tw369 Инструкция по эксплуатации
- ТРИД РК 122-2В4Р Инструкция по эксплуатации
- Oregon Scientific ws907 Инструкция по эксплуатации
- ТРИД РК 122-2В4С Инструкция по эксплуатации
- ТРИД РК 122-2В4С1Р Инструкция по эксплуатации
- ТРИД РК 122-2В5Р Инструкция по эксплуатации
- Olympus tough tg-835 black Инструкция по эксплуатации
- Olympus ws-831 2gb серебристый Инструкция по эксплуатации
- Olympus vn-7700 2gb черный Инструкция по эксплуатации
- ТРИД РК 122-2В4Р-485 Инструкция по эксплуатации
Скачать
Случайные обсуждения