Oregon Scientific wmr300 Инструкция по эксплуатации онлайн [6/15] 160575
![Oregon Scientific wmr300 Инструкция по эксплуатации онлайн [6/15] 160575](/views2/1176365/page6/bg6.png)
6
EN
TRANSMITTER BOX-BATTERY INSTALLATION
The solar panel on transmitter box is an energy saving feature, which is an
environmentally friendly way to provide power to the sensors and prolongs battery
life. It can entirely provide power to the supplied rechargeable battery. Sensors
can operate entirely on the rechargeable battery power. Locate the transmitter box
under direct sunlight for power supplying by the solar panel.
The rechargeable battery from factory is not with full
battery for long time use and it probably becomes
low battery during the shipping. We recommend
you to charge it for several hours by the connected
solar panel.
You can also purchase a power adapter separately
for directly providing power to the transmitter box.
The output voltage of the power adapter is 3V.
Route the adapter cable through the cable slot.
Please check the solar panel connection. If it
is not firmly plugged, please re-connect the
solar panel:
Plug the end of color-corded connector into corresponding socket in the transmitter
box as shown below and place the wires neatly inside the box.
To install the rechargeable battery:
Insert the battery into the battery compartment, matching the polarity +/-.
polarity +
CHANNEL SETTING
Your weather station system can expand with up to 8
sets of thermometer & humidity sensors, and one of
each of wind and rain sensors, which share one main
unit to display the weather readings. You can number
each transmitter box with an independent channel ID
(1-8) by sliding the switches.
Please follow the below chart to adjust the sliding switches of SW1:
NOTE
The below 0 in the chart represents off and 1 represents on.
CH PIN 2 PIN 3 PIN 4
Channel 1 0 0 0
Channel 2 0 0 1
Channel 3 0 1 0
Channel 4 0 1 1
Channel 5 1 0 0
Channel 6 1 0 1
Channel 7 1 1 0
Channel 8 1 1 1
For obviously indicate the status of your channel, you can turn on the LED light in
the corresponding transmitter box by sliding the PIN 1 switch to 1.
Function PIN 1
Disable LED 0
Enable LED 1
After setting, please turn off the LED light by sliding the PIN 1 switch to
0 to save
power, and then close the box by tightening the screws.
NOTE
The flashing LED indicates a normal transmission (See LED Light Indicator).
ON
1 2 3 4
RSN
SW1
1
0
REMOVE SETTING
For removing the previous setting from the transmitter box, you can press RESET
and KEY at a time, then only release RESET, red light flashes 5 times. Then
release KEY. The channel setting and calibrated wind direction are all removed
from the transmitter box.
LED LIGHT INDICATOR
There are three colors of LED lights in transmitter box, green, red and blue.
Different color combinations indicate different status.
Light Color Operations
Blue->green->red Flash once when you (Press and )release
RESET
Red flashes every second Flash 5 times then remove setting of all the
sensors from transmitter box (See Remove
setting section)
Red Wind direction calibration
(See Direction Calibration).
Blue flashes A normal transmission (WMR300A)
Green flashes A normal transmission (WMR300)
SENSORS INSTALLATION
You have three options to install the sensors.
The transmitter box is capable of transmitting data wirelessly an approximate
operating range of 300m (1000 feet). Ideal placements for the sensor would be
in any location on the roof of a building that is in an open area away from trees
or other obstructions preventing from the wind flow for an accurate reading.
Additionally, locate the transmitter box at the direct sunlight for power supplying
by the solar panel.
Solar panel facing: If you reside in the:
North Southern Hemisphere
South Northern Hemisphere
NOTE
Make sure the temperature and humidity sensor should be located at least
1.5 meters above the ground surface to avoid the ground temperature affecting
accuracy of the temperature and humidity sensor.
Option 1: All sensors are installed on a pole.
1
2
3
5
6
4
NOTE
Please take off the rain collector before installation and choose a pole with
the diameter that is about 32-45mm.
1. Locate one U-bolt without flat washers, lock washers and hex nuts into the gap
of the rain gauge (Figure 1).
2. Let the pole fully approach to the inner of the U-bolt (Figure 2).
3. Locate the other U-bolt without flat washers, lock washers and hex nuts into
the screw holes of the rain gauge (Figure 3).
4. Put the backing metal plate through the U-bolt and securely tighten two pairs of
the flat washers, lock washers and hex nuts over the plate (Figure 4) by wrench.
5. Insert the two ends of the first U-bolt into the screw holes of the wind sensor (Figure 5).
6. Tighten the other two pairs of flat washers, lock washers and hex nuts on the
U-bolt of the wind sensor by wrench (Figure 6).
NOTE
Make sure the water bubble in the balance indicator on the rain gauge
stay within the circle. Check the balance status regularly for an accurate rainfall
rate reading.
Содержание
- Contents 1
- Display unit 1
- Introduction 1
- Model wmr300 wmr300a 1
- Packaging contents 1
- Rain gauge 1
- Solar transmitter 1
- Ultra precision professional weather system 1
- User manual 1
- 12 13 14 15 4
- Bar chart 4
- Clock alarm weather forecast moon phase 4
- Dew point heat index wind chill 4
- Outdoor temperature humidity 4
- Sunrise sunset 4
- Wind speed wind direction 4
- Barometer 5
- Cable connections 5
- Installation 5
- Rainfall 5
- Set up rain sensor thermo hygro sensor 5
- Set up transmitter box 5
- Set up wind sensor 5
- Main unit batteries installation 7
- Manually set clock 7
- Pairing sensors remove sensors 7
- Alarm clock 8
- Clock reception 8
- Dewpoint heat index wind chill 8
- Moon phase 8
- Temperature and humidity 8
- Weather forecast 8
- Accumulated rainfall 9
- Bar chart 9
- Barometric pressure 9
- Direction calibration 9
- Rainfall 9
- Sunrise sunset 9
- Wind speed direction 9
- Data log 10
- Hourly records 10
- Max min of today monthly records 10
- Memory 10
- Backlight 11
- Maintainance 11
- Precautions 11
- To maintain the thermo hygro sensor 11
- Trouble shooting 11
- Indoor barometer 12
- Indoor relative humidity 12
- Indoor temperature 12
- Main unit 12
- Outdoor temperature humidity unit relative temperature 12
- Radio controlled atomic clock 12
- Rain gauge 12
- Relative humidity 12
- Solar rf transmitter box 12
- Specifications 12
- Wind sensor unit 12
- About oregon scientific 13
- Declaration of conformity 13
- Eu declaration of conformity 13
- Fcc statement 13
Похожие устройства
- Oregon Scientific cw101 Инструкция по эксплуатации
- Oregon Scientific bar218hg Инструкция по эксплуатации
- Oregon Scientific rar500n Инструкция по эксплуатации
- Oregon Scientific bar801 Инструкция по эксплуатации
- Oregon Scientific rrm222p Инструкция по эксплуатации
- Oregon Scientific bar223p Инструкция по эксплуатации
- ТРИД РК 112-1В3Р-485 Инструкция по эксплуатации
- Oregon Scientific tw396 Инструкция по эксплуатации
- Oregon Scientific rar213hg Инструкция по эксплуатации
- Oregon Scientific ws907 Инструкция по эксплуатации
- Oregon Scientific tw369 Инструкция по эксплуатации
- ТРИД РК 122-2В4Р Инструкция по эксплуатации
- Oregon Scientific ws907 Инструкция по эксплуатации
- ТРИД РК 122-2В4С Инструкция по эксплуатации
- ТРИД РК 122-2В4С1Р Инструкция по эксплуатации
- ТРИД РК 122-2В5Р Инструкция по эксплуатации
- Olympus tough tg-835 black Инструкция по эксплуатации
- Olympus ws-831 2gb серебристый Инструкция по эксплуатации
- Olympus vn-7700 2gb черный Инструкция по эксплуатации
- ТРИД РК 122-2В4Р-485 Инструкция по эксплуатации
Скачать
Случайные обсуждения