Polaris VEGA TS 5.5 Инструкция по эксплуатации онлайн [20/24] 19035

Polaris VEGA TS 5.5 Инструкция по эксплуатации онлайн [20/24] 19035
IV. Technical service regulation.
In the durative process of exploitation, when the warranty period is over, it is necessary to
make routine repairs once or twice a year.
- Turn the water heater off the main electrical supply
- Examine the water heater carefully , clean the water heater with the duster, check the water
pipes, remove the corrosion (if it is necessary to blow off) and cover with the layer of
protective lubrication.
ATTENTION!
Be careful! There mustn’t be any obstructions in the water outlet hose and shower- head.
- clean the injectors of the shower-head
- make the shifting of the screwed connections.
If the hydraulic drop (water flow) become worse, you should clean the rings of the water
heater and a strain (filter) which is set up at the inlet of the water heater.
V. Accessories
Model Accessories Shower Flexible pipe
1,5 м
Bracket Set of
rubber
gaskets
"S" for
kitchen
VEGA S
5.5
shower + + + +
sink + +
combined
+ + + + +
Additionally should be bought: an electric wire, a regular tap, a hose for the connection to the cold
water pipe.
VI. Trouble shouting
The functioning of the heater can be tested after installation as follows—turn it on and press
the "supply choice button" for maximum heat, with the shower head also set for Winter (few
"holes" open for maximum heat). Now, set the water flow to minimum. The heater is working
well if the water becomes hot.
There are common installation problems:
Problem Reason and solving method
When the water is very hot,
but only for a short
time, and then the water
becomes very hot again
briefly but for a short
time also.
It means that the heater has been installed incorrectly and
that the outlet is being obstructed by some tap or other
object. The tap must be located at the inlet of the heater!
Use only the parts supplied with the heater at the outlet!
The heater heated the water
as expected, but only
for a short time and not
again.
The protective fuse blew out, because it was unsuited to the
power of the heater installed.
The heater is not heating. Check to be sure that only parts supplied with the heater are

Содержание