Polaris GAMMA 3.5 Инструкция по эксплуатации онлайн [19/23] 19396

Polaris GAMMA 3.5 Инструкция по эксплуатации онлайн [19/23] 19396
- clean the injectors of the shower-head
- make the shifting of the screwed connections.
If the hydraulic drop (water flow) become worse, you should clean the rings of the water
heater and a strain (filter) which is set up at the inlet of the water heater.
V. Accessories
Model Accessories Shower Flexible pipe
1,5 м
Bracket Set of
rubber
gaskets
"S" for
kitchen
G A M M A
3.5
shower + + + +
sink + +
combined
+ + + + +
Additionally should be bought: an electric wire, a regular tap, a hose for the connection to the
cold water pipe.
VI. Trouble shouting
The functioning of the heater can be tested after installation as follows—turn it on and press
the "supply choice button" for maximum heat, with the shower head also set for Winter (few
"holes" open for maximum heat). Now, set the water flow to minimum. The heater is
working well if the water becomes hot.
There are common installation problems:
Problem Reason and solving method
When the water is very hot,
but only for a short
time, and then the
water becomes very
hot again briefly but
for a short time also.
It means that the heater has been installed incorrectly and
that the outlet is being obstructed by some tap or other
object. The tap must be located at the inlet of the heater!
Use only the parts supplied with the heater at the outlet!
The heater heated the water
as expected, but only
for a short time and
not again.
The protective fuse blew out, because it was unsuited to the
power of the heater installed.
The heater is not heating. Check to be sure that only parts supplied with the heater are
attached at the outlet! Make sure that the tap at the inlet
is a regular one, not a brass ball faucet/level tap, so that
the water flow can be finely controlled.
Common malfunctions that occur after prolonged, normal use of the heater
The water is very hot The water temperature can be reduced at the outlet by one of
the following actions:
the water temperature can be lowered by pressing one of
the "supply choice buttons", going from a maximum supply
to a lower level;
the water-flow can also be increased by means of the

Содержание