Yealink SIP-T19 E2 — настройка параметра Span to PC Port для IP-телефонов [743/841]

Yealink SIP-T19 E2 [743/841] Details of the configuration parameter
Troubleshooting
727
Details of the Configuration Parameter:
Parameter
Permitted Values
Default
network.span_to_pc_port
0 or 1
0
Description:
Enables or disables the IP phone to span data packets received from the WAN
(Internet) port to the PC (LAN) port.
0-Disabled
1-Enabled
If it is set to 1 (Enabled), all data packets from WAN port can be received by PC
port.
Note: If you change this parameter, the IP phone will reboot to make the change
take effect.
Web User Interface:
Network->Advanced->Span to PC->Span to PC Port
Phone User Interface:
None
To enable span to pc port via web user interface:
1. Click on Network->Advanced.