Yealink SIP-T19 E2 [326/401] Descriptions web setting path

Yealink SIP-T21 E2 [326/401] Descriptions web setting path
Yealink IP Phones Auto Provisioning Guide
316
Parameter
Permitted
Values
Descriptions
Web Setting Path
The default value is 0.
account.X.naptr_build
(SIP-T48G/T46G: X ranges from 1 to 16.
SIP-T42G: X ranges from 1 to 12.
SIP-T28P/T41P: X ranges from 1 to 6.
SIP-T26P/T22P: X ranges from 1 to 3.
SIP-T20P: X ranges from 1 to 2.)
0 or 1
It configures the way of SRV query for the IP
phone to be performed when no result is
returned from NAPTR query for account X.
0-SRV query using UDP only
1-SRV query using UDP, TCP and TLS.
The default value is 0.
For more information, refer to
Server
Redundancy on Yealink IP Phones
.
account.X.fallback.redundancy_type
(SIP-T48G/T46G: X ranges from 1 to 16.
SIP-T42G: X ranges from 1 to 12.
SIP-T28P/T41P: X ranges from 1 to 6.
SIP-T26P/T22P: X ranges from 1 to 3.
SIP-T20P: X ranges from 1 to 2.)
0 or 1
It configures the registration mode for account
X in fallback mode.
0-Concurrent registration
1-Successive registration
The default value is 0.
For more information, refer to
Server
Redundancy on Yealink IP Phones
.
account.X.fallback.timeout
(SIP-T48G/T46G: X ranges from 1 to 16.
SIP-T42G: X ranges from 1 to 12.
SIP-T28P/T41P: X ranges from 1 to 6.
Integer from
10 to
2147483647
It configures the time interval (in seconds) for
the IP phone to detect whether the working
server is available by sending the registration
request for account X after the fallback server
takes over call control.