Graco C02025 [11/20] Service

310543 11
Service
AMV Reassembly (C02026)
This procedure describes how to reassemble the pistol
grip metering valve. Refer to Parts information on
page 15.
NOTES:
The numbers in parentheses in the text refer to
reference numbers in the parts drawings and parts
lists.
Clean all the parts thoroughly before reassembling
the AMV. Check them carefully for damage or
wear, replacing parts as needed.
Metering Valve Reassembly Procedure
To reassemble the metering valve, refer to the AMV
Reassembly procedure on page 9.
Gun Handle Reassembly Procedure
To reassemble the gun handle, perform the following
procedure:
1. Install the spring (110), trigger (109), and roll pin
(112) in the gun handle (108).
2. Install the roll pin (111) that controls the tension of
the spring (110) in the gun handle (108).
3. Install the valve (106) that controls the air inlet
pressure to the gun.
4. Reconnect the 10-32 x 1/4” fitting (105) that con-
nects the tubing (104) to the gun handle (108).
5. Reinstall the four socket-head screws (103) to lock
the gun handle (108) components together.
6. Mount and secure the metering valve (101) to the
mounting block (113) using the socket-head screw
(107) and the second screw (not listed).
7. Reconnect the tubing (104) to the elbow (102) on
the metering valve (101).
Metering Valve Air and Fluid Connections
To reconnect the AMV to the air and fluid lines, per-
form the following procedure:
1. Reconnect the air and fluid hoses.
2. Turn on the air pressure and apply power to the
fluid supply system.
3. Check the air and fluid hoses on the AMV for
leakage.
4. Return the AMV to normal operating condition.