Graco 24F947 [9/14] Flushing
![Graco 24F878 [9/14] Flushing](/views2/1193708/page9/bg9.png)
Operation
3A1189G 9
Drum Mounting Bracket (2): Model 24F947 or
24M499
Drum mounted DEF System Models 24F947 or 24M499
include a Mounting Bracket Kit containing the following
parts - Screws (2a), Screws (2b), Washers (2d), Hex
Nuts (2e), Mounting Plate (2f), Nozzle Bath Holder (2g),
Nozzle Holder Bracket (2h) and screws (2j). The Mount-
ing Bracket and Nozzle Holder are also identified as
item M on the Typical Installation Diagram provided on
page 5.
1. Assemble pump to bracket.
2. Position drum mounting plate (2f) on top of drum.
3. Use screws (2b), nuts (2e) and washers (2d) (pro-
vided) to install mounting plate to pump.
4. Align holes in nozzle holder bracket (2h) with holes
in plate (2f). Use screws (2b), nuts (2e) and wash-
ers (2d)(provided) to install meter tray plate.
5. Place nozzle bath tray (2g) in nozzle holder bracket
(2h). Fill bath with water. Keep nozzle bath tray filled
with water at all times.
Flushing
After initial assembly and installation, flush the entire
dispensing system by pumping 5-10 gallons of DEF
through it. This purges the system of air and insures any
impurities that may have been in the system are washed
out.
Dispose of the DEF used to flush the system using
approved DEF handling procedures. Do not return the
fluid to the drum or tote or use it in a vehicle.
Operation
Alpha letters included in the following instructions refer
to letters shown in Typical Installation examples (F
IG. 1 -
F
IG. 2, pages 4 - 5).
Priming
1. Hold dispensing nozzle (G) open while at the same
time slowly opening the pump air regulator (D) until
the pump (A) starts to cycle.
2. Allow the pump to cycle slowly until all the air has
been pushed out of the lines and the pump is
primed.
3. If the pump doesn’t prime crack the pump outlet fit-
ting and slowly run the pump until you see fluid fill-
ing the pump.
4. Then tighten the connection.
NOTICE
To maintain the integrity and purity of the AUS32
(Aqueous Urea Solution 32.5%) and ensure proper
operation of equipment:
• Once the system is assembled it must remain
sealed to insure the integrity of the fluid. Break-
ing the seal on the system can lead to fluid con-
tamination.
• After dispensing DEF, drain all the fluid from the
nozzle, making sure it is pointing downward
when stored in the nozzle holder. DEF remaining
in the nozzle tip and exposed to air will crystallize
and can plug the nozzle.
• DO NOT lay the dispensing nozzle on the ground
or on any surface that may contaminate the noz-
zle tip and compromise the purity of the DEF.
Содержание
- A1189g 1
- Diesel exhaust fluid def system 1
- For pumping diesel exhaust fluid not approved for use in european explosive atmosphere locations for professional use only 1
- Important safety instructions 1
- Instructions 1
- Model no 24f531 1
- Model no 24f878 1
- Model no 24f947 1
- Model no 24m499 1
- Related manuals 1
- Warning 2
- Warnings 2
- Warning 3
- Installation 4
- Model 24f531 wall mounted with meter model 24f878 wall mounted no meter 4
- Typical installations 4
- Model 24f947 5
- Model 24f947 drum mounted without meter model 24m499 drum mounted with meter 5
- Model 24m499 5
- General installation information 6
- Identification label for ce mark 6
- Installation date 6
- Meter 10 installation models 24f531 and 24m499 8
- Mounting bracket 2 installation 8
- Nozzle 3 installation models 24f878 and 24f947 8
- Flushing 9
- Operation 9
- Priming 9
- Wall mounted with meter model 24f531 wall mounted without meter model 24f878 10
- Drum mounted without meter model 24f947 drum mounted with meter model 24m499 11
- A screw cap hex head 4 2b screw thumb 1 4 20 x 2 2 2d washer plain 12 2e nut hex 6 2f plate pump mount 1 2g holder nozzle bath 1 2h bracket nozzle holder 1 2j screw hh 1 4 x 20 x 0 5 not shown 2 12
- A screw cap hex head not shown 4 2b screw cap hex head 4 2c washer not shown 4 2d washer plain 14 2e nut hex 7 2f plate pump mount 1 2g holder nozzle bath 1 2h bracket nozzle holder 1 2j screw hh 1 4 x 20 x 0 5 not shown 3 12
- Bracket 2 kits 12
- Bracket 24f870 models 24f531 24f878 2 bracket 24f679 model 24f947 24m499 12
- Technical data 12
- Us metric 12
- Us metric 13
- Copyright 2011 graco inc is registered to iso 9001 www graco com february 2011 revised june 2014 14
- Graco headquarters minneapolis international offices belgium china japan korea 14
- Graco inc p o box 1441 minneapolis mn 55440 1441 14
- Graco information 14
- Graco standard warranty 14
- To place an order contact your graco distributor or call to identify the nearest distributor phone 612 623 6928 or toll free 1 800 533 9655 fax 612 378 3590 14
Похожие устройства
- Graco 24F947 Технические характеристики
- Graco 24M499 Инструкция по эксплуатации
- Graco 24M499 Технические характеристики
- Graco Python XL 1/4" Инструкция по эксплуатации
- Graco Python XL 1/4" Технические характеристики
- Graco Python XL 3/8" Инструкция по эксплуатации
- Graco Python XL 3/8" Технические характеристики
- Graco Python XL 1/2" Инструкция по эксплуатации
- Graco Python XL 1/2" Технические характеристики
- Graco Python XL 5/8" Инструкция по эксплуатации
- Graco Python XL 5/8" Технические характеристики
- Graco Python XL 3/4" Инструкция по эксплуатации
- Graco Python XL 3/4" Технические характеристики
- Graco Python 1/8" Инструкция по эксплуатации
- Graco Python 1/8" Брошюра
- Graco Python 3/16" Инструкция по эксплуатации
- Graco Python 3/16" Технические характеристики
- Graco Python 1/4" Инструкция по эксплуатации
- Graco Python 1/4" Технические характеристики
- Graco Python 3/8" Инструкция по эксплуатации