Moxa EDS-518A-MM-SC [76/109] Configuring ieee 802 x

Moxa EDS-518A-MM-SC [76/109] Configuring ieee 802 x
Moxa Managed Ethernet Switches Featured Functions
3-64
server as the authentication server, the authenticator and the authentication server exchange EAP frames
between each other.
Authentication can be initiated either by the supplicant or the authenticator. When the supplicant initiates the
authentication process, it sends an EAPOL-Start frame to the authenticator. When the authenticator initiates
the authentication process or when it receives an EAPOL Start frame, it sends an EAP Request/Identity
frame to ask for the username of the supplicant.
Configuring Static Port Lock
The Moxa switch supports adding unicast groups manually if required.
Static Unicast MAC Address
Setting Description Factory Default
MAC Address Adds the static unicast MAC address into the address table. None
Port Associates the static address to a dedicated port. 1 or 1-1
Configuring IEEE 802.1X
Database Option
Setting Description Factory Default
Local
(Max. of 32 users)
Select this option when setting the Local User Database as the
authentication database.
Local
Radius Select this option to set an external RADIUS server as the
authentication database. The authentication mechanism is
EAP-MD5.
Local
Radius, Local
Select this option to make using an external RADIUS server as
the authentication database the first priority. The
authentication mechanism is EAP-
MD5 The first priority is to set
the Local User Database as the authentication database.
Local

Содержание

Похожие устройства