Moxa PT-508-2MTRJ-48 [6/15] Warning warning
![Moxa PT-508-MM-SC-24 [6/15] Warning warning](/views2/1195796/page6/bg6.png)
- 6 -
Wall Mounting (optional)
For added convenience, the PT-508 can be wall mounted as illustrated
below.
STEP 1: Remove the
aluminum DIN
-Rail
attachment plate from
the
PT
-508
’s rear panel, and then
attach the wall mount plates
with
6 M3 screws, as shown
on
the right.
STEP 2: Mounting the PT-508 to a wall requires 4
screws. Use the
PT-508, with wall mount plates attached,
as a guide to mark the correct locations for the
4
screws.
The heads of the screws should be less than 6.0 mm in
diameter, and the shafts should be less than 3.5 mm in
diameter, as shown on the righ
t.
NOTE
Test the screw’s head and shank size by inserting the screw into
one of the keyhole
-shaped apertures of the wall mounting plates
before screwing it into the wall.
DO NOT screw the screws all the way in—leave a space of about 2 mm to
allow room for sliding the wall mount panel between the wall and the
screws.
STEP 3: After the screws are fixed into the wall, insert the four screw
heads through the large opening of the keyhole-shaped apertures, and
then slide the PT-508 downwards. Tighten the 4 screws for added
stability.
Wiring Requirements
WARNING
Safety First!
Be sure the power cord is disconnected before installing and/or
wiring your
PT-508.
Calculate the maximum possible current in each power
wire and
common wire. Observe all electrical codes dictating the
maximum current allowed for each wire size. If the current goes
above the maximum rating, the wiring could overheat, causing
serious damage to your equipment.
Содержание
- Fifth edition january 2014 1
- Moxa powertrans switch 1
- Pt 508 series hardware installation guide 1
- Package checklist 2
- Panel layout of the pt 508 3
- Mounting dimensions unit mm 4
- Din rail mounting 5
- Wall mounting optional 6
- Warning warning 6
- Wiring requirements 6
- Attention 7
- Grounding the powertrans switch 7
- Attention 8
- Take the following steps to wire the redundant power inputs 8
- Wiring the redundant power inputs 24 48 vdc models 8
- Wiring the relay contact 8
- Attention 9
- Wiring the digital inputs 9
- Wiring the power input 110 220 vdc vac model 9
- 100baset x ethernet port connection 10
- Pin assignments 10
- Attention 11
- Basefx ethernet port connection 11
- Front panel leds 12
- Auto mdi mdi x connection 13
- Fiber ports 13
- Specifications 13
Похожие устройства
- CAS CUW-620HV Руководство по эксплуатации
- CAS CUW-8200S Руководство по эксплуатации
- Moxa PT-508-2MTRJ-48 Технические характеристики
- CAS CUW-820S Руководство по эксплуатации
- Moxa PT-508-2MTRJ-48 Руководство по использованию командной строки
- CAS CUX-2200H Руководство по эксплуатации
- CAS CUX-220H Руководство по эксплуатации
- CAS CUX-4200H Руководство по эксплуатации
- Moxa PT-508-2MTRJ-HV Инструкция по эксплуатации
- Moxa PT-508-2MTRJ-HV Руководство пользователя Англ.
- CAS CUX-420H Руководство по эксплуатации
- CAS CUX-420S Руководство по эксплуатации
- Moxa PT-508-2MTRJ-HV Руководство по аппаратной части
- CAS CUX-6200H Руководство по эксплуатации
- Moxa PT-508-2MTRJ-HV Руководство по использованию командной строки
- CAS CUX-620H Руководство по эксплуатации
- Moxa PT-508-2MTRJ-HV Технические характеристики
- CAS CUX-8200S Руководство по эксплуатации
- CAS CUX-820S Руководство по эксплуатации
- Moxa PT-510-MM-SC-24 Инструкция по эксплуатации