Moxa EDR-G903 [12/74] Clock timezone

Moxa EDR-G902 [12/74] Clock timezone
CLI Command Set User's Manual System Functions
1-9
end-date The date when summer time offset end
month From 'Jan', 'January' or '1' to 'Dec', 'December', or '12'
week From '1st' or '1' to 'Last' or '6'
day From 'Sun', 'Sunday' or '1' to 'Sat', 'Saturday' or '7'
hour 0 ~ 23
offset Summer time offset
offset-hour 1 ~ 12
Defaults N/A
Command
Modes
Global configuration
Usage
Guidelines
When configuring the summer time offset, the start-date and end-date must be configured
correctly first.
Examples router(config)# clock timezon gmt -4
Error
messages
Invalid parameter
Month must be configured as 'Jan', 'January' or a numerical '1'.
Week must be configured as '1st', '2nd', '3rd', '4th', '5th' or 'Last'
Day must be configured as 'Sun', 'Sunday' or a numerical '1'.
Hour must be in the range from 0 to 23.
Please input the correct start/end date of the summer time first!
Hour offset is out of range.
Related
commands
show clock
clock timezone
Use the clock timezone global configuration command on the router to set the current time zone.
Command
clock timezone gmt offset-hour
Syntax
Description
clock Configure time-of-day clock
timezone Time zone hour shifting
gmt Greenwich Mean Time
offset-hour -12 ~ 12
Defaults N/A
Command
Modes
Global configuration
Usage
Guidelines
N/A
Examples router(config)# clock timezon gmt -4
Error
messages
Hour offset is out of range
Related
commands
show clock