Moxa IKS-6728A-4GTXSFP-48-T [10/11] Rack mounting instructions
![Moxa IM-6700A-8PoE [10/11] Rack mounting instructions](/views2/1196580/page10/bga.png)
- 10 -
Storage
Temp.
-40 to 85°C (-40 to 185°F)
Ambient
Relative
Humidity
5 to 95% (non-condensing)
Standards and Certifications
Safety
UL 60950-1, EN 60950-1
EMI
FCC Part 15 Subpart B Class A, EN 55022 Class A
EMS
EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 3, EN 61000-4-
5 (Surge) Level
3, EN 61000-4-6 (CS) Level 3, EN 61000-4-8, EN
61000-4-11
Note: For better conductive radiation immunity,
STP cable
is recommended.
Rail Traffic
EN 50121-4
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-32
Vibration
IEC 60068-2-6
Warranty
Warranty
Period
5 years
Details
See www.moxa.com/warranty
Rack Mounting Instructions
1. Elevated Operating Ambient: If installed in a closed or multi-unit
rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature
(Tma) specified by the manufacturer.
2. Reduced Air Flow: Installation of the equipment in a rack should
be such that the amount of air flow required for safe operation of the
equipment is not compromised.
3. Mechanical Loading: Mounting of the equipment in the rack
should be such that a hazardous condition is not achieved due to
uneven mechanical loading.
4. Circuit Overloading: Consideration should be given to the
connection of the equipment to the supply circuit and the effect that
overloading of the circuits might have on overcurrent protection and
supply wiring. Appropriate consideration of equipment nameplate
ratings should be used when addressing this concern.
5. Reliable Grounding: Reliable grounding of rack-mounted
equipment should be maintained. Particular attention should be
given to supply connections other than direct connections to the
branch circuit (e.g. use of power strips).
NOTE
The rackmount ears can be equipped on the front or rear of Moxa
IKS-6700A/IKS-6728-8PoE switch.
Restricted Access Locations
• This equipment is intended to be used in Restricted
Access Locations, such as a computer room, with
access limited to SERVICE PERSONAL or USERS
Содержание
- First edition september 2014 1
- Hardware installation guide 1
- Iks 6700a and iks 6728a 8poe series 1
- Package checklist 2
- Panel layouts 2
- Dimensions 3
- Fast ethernet interface modules im 6700a 3
- Series 3
- Ac power inlets 4
- Connecting the power inputs 4
- Grounding the moxa industrial rackmount switch 4
- Warning 4
- Dc power terminal blocks 5
- Usb connection 5
- Wiring the relay contact 5
- Led indicators 6
- The reset button 6
- Specifications 8
- Rack mounting instructions 10
- Restricted access locations 10
Похожие устройства
- Gunter & Hauer GH 640 IVR Инструкция по эксплуатации
- Moxa IKS-6728A-4GTXSFP-48-T Руководство по использованию командной строки
- Moxa IKS-6728A-4GTXSFP-48-T Руководство по созданию резервированных сетей
- Moxa IKS-6728A-4GTXSFP-48-T Технические характеристики
- Gunter & Hauer GL 641 CB Руководство пользователя
- Gunter & Hauer GH 605 EX Руководство пользователя
- Gunter & Hauer GL 741 CB Руководство пользователя
- Moxa IKS-6728A-4GTXSFP-48-48-T Инструкция по эксплуатации
- Moxa IKS-6728A-4GTXSFP-48-48-T Руководство по аппаратной части
- Gunter & Hauer S 6 W Руководство пользователя
- Gunter & Hauer GH 901 CX Руководство пользователя
- Moxa IKS-6728A-4GTXSFP-48-48-T Руководство по использованию командной строки
- Moxa IKS-6728A-4GTXSFP-48-48-T Руководство по созданию резервированных сетей
- Moxa IKS-6728A-4GTXSFP-48-48-T Технические характеристики
- Gunter & Hauer S 9 B Руководство пользователя
- Moxa IKS-6728A-4GTXSFP-HV-T Инструкция по эксплуатации
- Moxa IKS-6728A-4GTXSFP-HV-T Руководство по аппаратной части
- Gunter & Hauer S 6 B Руководство пользователя
- Moxa IKS-6728A-4GTXSFP-HV-T Руководство по использованию командной строки
- Moxa IKS-6728A-4GTXSFP-HV-T Руководство по созданию резервированных сетей