Moxa IMC-101-S-SC-80 [7/14] Attention
![Moxa IMC-101-M-ST-IEX [7/14] Attention](/views2/1197866/page7/bg7.png)
- 7 -
WARNING
This equipment has been evaluated as EEx nC IIC T4 equipment
under DEMKO Certificate No. 03 ATEX 0324537U. Each module
is
marked with
II 3G and is suitable for use in Zone 2 Explosive
Atmospheres. Devices must be installed in a minimum IP54
enclosure as defined in IEC 60529 and EN 60529.
ATTENTION
This unit is a built
-in type. During installation into certain end
equipment, it must comply with fire enclosure stipulations of IEC
60950/EN60950, or similar statements.
SAFETY FIRST
Be sure to disconnect the power cord before installing and/or
wiring your Moxa IMC-101.
SAFETY FIRST
Calculate the maximum possible current in each power wire and
common wire. Observe all electrical codes dictating the
maximum current allowable for each wire size.
If the current goes above the maximum ratings, the wiring could
overheat, causing serious damage to your equipment.
You should also pay attention to the following points:
• Use separate paths to route wiring for power and devices. If power
wiring and device wiring paths must cross, make sure the wires are
perpendicular at the intersection point.
NOTE: Do not run signal or communications wiring and power wiring in
the same wire conduit. To avoid interference, wires with different signal
characteristics should be routed separately.
• You can use the type of signal transmitted through a wire to
determine which wires should be kept separate. The rule of thumb is
that wiring that shares similar electrical characteristics can be
bundled together.
• Keep input wiring and output wiring separated.
• It is strongly advised that you label wiring to all devices in the system
when necessary.
Grounding the IMC-101
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the
ground screw to the grounding surface prior to connecting devices.
Содержание
- Imc 101 series hardware installation guide 1
- Moxa industrial media converter 1
- Seventh edition august 2013 1
- Features 2
- Overview 2
- Package checklist 2
- Panel layout of imc 101 series 3
- Mounting dimensions 4
- Din rail mounting 5
- Wall mounting optional 5
- Atex and iecex information 6
- Warning 6
- Warning warning 6
- Wiring requirements 6
- Attention 7
- Grounding the imc 101 7
- Safety first 7
- Warning 7
- Attention 8
- Communication connections 8
- Wiring the alarm contact 8
- Wiring the redundant power inputs 8
- 100baset x ethernet port connection 9
- Basefx ethernet port connection 9
- Alarm contact 10
- Attention 10
- Redundant power inputs 10
- Dip switch setting 11
- Led indicators 11
- Auto mdi mdi x connection 12
- Auto negotiation and speed sensing 12
- Dual speed functionality and switching 12
- Specifications 12
- Serial number 14
Похожие устройства
- Moxa IMC-101-S-SC-80 Технические характеристики
- Moxa IMC-101-S-SC-80-T Инструкция по эксплуатации
- Moxa IMC-101-S-SC-80-T Руководство пользователя Англ.
- Moxa IMC-101-S-SC-80-T Технические характеристики
- Moxa IMC-101G Инструкция по эксплуатации
- Moxa IMC-101G Руководство пользователя Англ.
- Moxa IMC-101G Технические характеристики
- Moxa IMC-101G-T Инструкция по эксплуатации
- Moxa IMC-101G-T Руководство пользователя Англ.
- Moxa IMC-101G-T Технические характеристики
- Moxa IMC-101G-IEX Инструкция по эксплуатации
- Moxa IMC-101G-IEX Руководство пользователя Англ.
- Moxa IMC-101G-IEX Технические характеристики
- Moxa IMC-101G-T-IEX Инструкция по эксплуатации
- Moxa IMC-101G-T-IEX Руководство пользователя Англ.
- Moxa IMC-101G-T-IEX Технические характеристики
- MartinLogan Motion Vision X Руководство пользователя
- MartinLogan Motion 60XT Руководство пользователя
- MartinLogan Motion 50XT Руководство пользователя
- Moxa IMC-P101-M-SC Инструкция по эксплуатации