DA-710 XPE User’s Manual Software Configuration
3. When the system has rebooted, type fbwfmgr /displayconfig in the command prompt again to
confirm thatthe status has been changed to enabled. The default folder for FBWF will be
\temp. Type fbwfmgr /help for more detailed information.
C:\> fbwfmgr /displayconfig
File-based write filter configuration for the current session:
filter state: enabled.
overlay cache data compression state: disabled.
overlay cache threshold: 64 MB.
overlay cache pre-allocation: disabled.
size display: actual mode.
protected volume list:
\Device\HarddiskVolume3
write through list of each protected volume:
\Device\HarddiskVolume3:
\temp
File-based write filter configuration for the next session:
filter state: enabled.
overlay cache data compression state: disabled.
overlay cache threshold: 64 MB.
overlay cache pre-allocation: disabled.
size display: actual mode.
protected volume list:
\Device\HarddiskVolume3
write through list of each protected volume:
\Device\HarddiskVolume3:
\temp