Moxa UC-7122-CE [6/46] Overview
![Moxa UC-7112-LX [6/46] Overview](/views2/1199633/page6/bg6.png)
UC-7101/7110/7112 Software User’s Manual Introduction
1-2
Overview
The UC-7101/7110/7112 Series of mini RISC-based communication platforms are ideal for your
embedded applications. The UC-7101/7110/7112 come with RS-232/422/485 serial ports and
10/100 Mbps Ethernet LAN ports to provide users with a versatile communication platform.
The UC-7101/7110/7112 use the ARM9 RISC CPU. Unlike the X86 CPU, which uses a CISC
design, the ARM9’s RISC design architecture and modern semiconductor technology provide the
UC-7101/7110/7112 with a powerful computing engine and communication functions, but without
generating too much heat. The built-in 8 MB NOR Flash ROM and 16 MB SDRAM give you
enough storage capacity, and an additional SD socket provides you with flexible storage expansion
to run a wide range of applications. The LAN ports built into the ARM9 make the
UC-7101/7110/7112 ideal communication platforms for data acquisition and protocol conversion
applications, and the RS-232/422/485 serial ports allow you to connect a variety of serial devices.
The pre-installed µClinux operating system provides an open software operating system for
software program development. Software written for desktop PCs is easily ported to the
UC-7101/7110/7112 with a GNU cross complier, so that you will not need to spend time
modifying existing software code. The operating system, device drivers, and your own software
can all be stored in the UC-7101/7110/7112 Flash memory.
Package Checklist
The following models of the UC-7101/7110/7112 Series are currently available:
UC-7101-LX
Mini RISC-based Ready-to-Run Embedded Computer with 1 Serial Port, 1 Ethernet port, SD, and
μClinux operating system
UC-7110-LX
Mini RISC-based Ready-to-Run Embedded Computer with 2 Serial Ports, Dual Ethernet, μClinux
OS
UC-7112-LX
Mini RISC-based Ready-to-Run Embedded Computer with 2 Serial Ports, Dual Ethernet, SD,
μClinux OS
The UC-7101/7110/7112 embedded computers are shipped with the following items:
1 UC-7101/7110/7112
UC-7101/7110/7112 Quick Installation Guide
Document and Software CD
Ethernet cross-over cable: RJ45 to RJ45, 100 cm
Console port cable: CBL-4PINDB9F-100 (4-pin header to female DB9 cable, 100 cm)
Universal Power Adaptor
Product Warranty Statement
Optional Accessories
DK-35A DIN-Rail Mounting Kit (35 mm)
NOTE: Please notify your sales representative if any of the above items are missing or damaged.
Содержание
- Ninth edition april 2015 1
- Uc 7101 7110 7112 user s manual 1
- Www moxa com product 1
- Copyright notice 2
- Disclaimer 2
- Technical support contact information 2
- Trademarks 2
- Uc 7101 7110 7112 user s manual 2
- Www moxa com support 2
- Table of contents 3
- Introduction 5
- Overview 6
- Package checklist 6
- Hardware specifications 7
- Product features 7
- Product specifications 7
- Software specifications 8
- Getting started 9
- Connecting the uc 7101 7110 7112 to a pc 10
- Console port 10
- Powering on the uc 7101 7110 7112 10
- Telnet 11
- Configuring the ethernet interface 12
- Developing your applications 14
- Installing the uc 7101 7110 7112 tool chain 14
- Compiling hello c 15
- Uploading hello to the uc 7101 7110 7112 15
- Running hello on the uc 7101 7110 7112 16
- Sample makefile code 17
- Software package 19
- Uc 7101 7110 7112 software architecture 20
- Journaling flash file system jffs2 21
- Uc 7101 7110 7112 software package 22
- Configuring uc 7101 7110 7112 23
- Enabling and disabling daemons 24
- How to enable disable etc inittab www server 24
- How to enable disable telnet ftp server 24
- How to enable network time protocol 24
- How to update the system time periodically with network time protocol 24
- Adding a web page 25
- Iptables 25
- Define policy for chain rules 27
- Observe and erase chain rules 27
- Append or delete rules 28
- Nat example 29
- The ip addresses of all packets leaving lan1 are changed to 192 68 27 you will need to load the module ipt_masquerade 29
- Uc 7101 7110 7112 software user s manual configuring uc 7101 7110 7112 29
- Configuring dial in dial out service 30
- Connect using a modem 30
- Dial in service 30
- Dial out service 30
- Direct cable connection 30
- Enabling nat at bootup 30
- Configuring pppoe 31
- Dynamic driver module load unload 31
- How to mount a remote nfs server 31
- Upgrading the kernel 32
- Upgrading the root file system user directory 33
- Autostarting user applications on bootup 34
- Checking the kernel and root file system versions 34
- Loading factory defaults 34
- Uc 7101 7110 7112 device api 35
- Buzzer 36
- Rtc real time clock 36
- Uart interface 36
- Wdt watch dog timer 37
- Editor 41
- File manager 41
- System commands 41
- Μclinux normal command utility collection 41
- Moxa special utilities 42
- Network 42
- Process 42
- Snmp agent with mib ii rs 232 like group 43
Похожие устройства
- Moxa UC-7122-CE Руководство по быстрой установке
- Moxa UC-7122-T-CE Инструкция по эксплуатации
- Moxa UC-7122-T-CE Руководство по аппаратной части
- Moxa UC-7122-T-CE Руководство по программной части
- Moxa UC-7122-T-CE Технические характеристики
- Moxa UC-7122-T-CE Руководство по быстрой установке
- Moxa UC-7124-CE Инструкция по эксплуатации
- Moxa UC-7124-CE Руководство по аппаратной части
- Moxa UC-7124-CE Руководство по программной части
- Moxa UC-7124-CE Технические характеристики
- Moxa UC-7124-CE Руководство по быстрой установке
- Moxa UC-7124-T-CE Инструкция по эксплуатации
- Moxa UC-7124-T-CE Руководство по аппаратной части
- Moxa UC-7124-T-CE Руководство по программной части
- Moxa UC-7124-T-CE Технические характеристики
- Moxa UC-7124-T-CE Руководство по быстрой установке
- Moxa UC-8112-ME-T-LX Инструкция по эксплуатации
- Moxa UC-8112-ME-T-LX Руководство по аппаратной части
- Moxa UC-8112-ME-T-LX Технические характеристики
- Moxa UC-8112-LX Инструкция по эксплуатации