Moxa UC-8132-T-LX [11/23] Bdiagnosing device and subsystem failures

Moxa UC-8132-LX-CG [11/23] Bdiagnosing device and subsystem failures
UC-8112-ME-T Series Hardware Introduction
2-4
Diagnosing Device and Subsystem Failures
The red LED will start blinking once you press the function button (FN). Keep the button pressed until the green
LED is lit for the first time and then release the button to enter diagnostic mode to check which peripherals are
available on the UC-8112-ME-T-LX. When the diagnostic program is running, the red LED will blink.
Status Red LED Yellow LED Green LED
Diagnostics program is executing Blinking Off On
The following two tables describe the diagnostics results related to hardware defects and system operation.
Hardware Defects
If you observe any of these hardware issues, contact Moxa Support for further instructions.
Status Red LED Yellow LED Green LED
UART1 device issue On On Off
UART2 device issue
(except UC-8131)
On On Blinking
LAN 1 device issue On Off Off
LAN 2 device issue On Off Blinking
Button device issue On Blinking Off
TPM device issue On Blinking Blinking
LED device issue On Off Off
System Operation
If you observe any of the following issues, check the item indicated by the LEDs.
Status Red LED Yellow LED Green LED
CPU usage (over 90%) Blinking On Off
RAM usage (over 90%) Off On Off
Disk usage (over 90%) Off On Blinking
File system corrupted Blinking On Blinking
Reset to Factory Default
Press and hold the function button (FN) continuously for at least 5 seconds to load the factory default
configuration. After the factory default configuration has been loaded, the system will reboot automatically.
The Power LED will blink on and off for the first 5 seconds, and then maintain a steady glow once the system
has rebooted.
We recommend that you only use this function if the software is not working properly and you want to load
factory default settings. The Reset to Default functionality is not designed to hard reboot the UC-8112-ME-T.
ATTENTION
Reset to D
efault will erase all the data stored on the boot storage
Please back up your files before resetting the system to
the factory default configuration
. All the data stored
in the UC
-8100-LX‘s boot storage will be erased when it is reset to the factory default configuration.
Real-Time Clock
The UC-8112-ME-T’s real-time clock is powered by a lithium battery. We strongly recommend that you do not
replace the lithium battery without help from a qualified Moxa support engineer. If you need to change the
battery, contact the Moxa RMA service team.