Moxa V2406-24I-CT-T-XPE [48/81] Ethernet bridging for private networks on the same subnet

Moxa V2406-24I-CT-LX [48/81] Ethernet bridging for private networks on the same subnet
V2406/2422/2426 Linux User’s Manual Managing Communications
3-24
ATTENTION
You can create link symbols to start the OpenVPN service at boot time:
# ln -sf /etc/init.d/openvpn /etc/rc2.d/S16openvpn
To stop the service, you should create these links:
# ln -sf /etc/init.d/openvpn /etc/rc0.d/K80openvpn
# ln -sf /etc/init.d/openvpn /etc/rc6.d/K80openvpn
8. On each OpenVPN machine, check the routing table by typing the command
# route
Destination Gateway Genmsk Flags Metric Ref Use Iface
192.168.5.0 0.0.0.0 255.255.255.0 U 0 0 0 eth2
192.168.4.0 0.0.0.0 255.255.255.0 U 0 0 0 br0
192.168.3.0 0.0.0.0 255.255.255.0 U 0 0 0 eth0
192.168.30.0 0.0.0.0 255.255.255.0 U 0 0 0 eth3
192.168.8.0 0.0.0.0 255.255.255.0 U 0 0 0 br0
Interface eth1 and device tap0 both connect to the bridging interface, and the virtual device tun sits on
top of tap0. This ensures that all traffic coming to this bridge from internal networks connected to interface
eth1 write to the TAP/TUN device that the OpenVPN program monitors. Once the OpenVPN program
detects traffic on the virtual device, it sends the traffic to its peer.
9. To create an indirect connection to Host B from Host A, you need to add the following routing item:
# route add –net 192.168.4.0 netmask 255.255.255.0 dev eth0
To create an indirect connection to Host A from Host B, you need to add the following routing item:
# route add –net 192.168.2.0 netmask 255.255.255.0 dev eth0
Now ping Host B from Host A by typing:
# ping 192.168.4.174
A successful ping indicates that you have created a VPN system that only allows authorized users from one
internal network to access users at the remote site. For this system, all data is transmitted by UDP packets
on port 5000 between OpenVPN peers.
10. To shut down OpenVPN programs, type the command:
# killall -TERM openvpn
Ethernet Bridging for Private Networks on the Same Subnet
1. Set up four machines, as shown in the following diagram.

Содержание

Похожие устройства