Moxa MPC-2197X [58/70] Connecting to the console interface

Moxa MPC-2157Z-T [58/70] Connecting to the console interface
MPC-2190 Hardware Display Control Interface
6-2
Connecting to the Console Interface
If you want to use the commands in Appendix B to adjust the display settings, you need to connect to the
display using the console interface. The following steps describe how.
The console interface is listed as the COM3 interface within the operating system. To communicate with the
display over COM3, we suggest you use terminal emulator for Telnet, like Moxa’s PComm.
When launching the PComm Terminal Emulator, configure the following settings:
1. Select Port Manager, and then select Open.
2. Configure the Property settings:
Protocol: Serial
Serial Parameters: COM3
Baud rate: 9600
Data bits: 8
Parity: None
Stop bits: 1
RTS state: ON
DTR state: ON
When finished, click OK.