M-Audio DMAN [45/52] Dos troubleshooting
![M-Audio DMAN [45/52] Dos troubleshooting](/views2/1020087/page45/bg2d.png)
45
DOS Troubleshooting
When you run DMAN DOS-based diagnostics application, each
test passes or fails on the basis of meeting two criteria. Each test
checks that DMAN can be contacted at the parameter in question,
and also pauses for a period of time to ensure that no IRQ, DMA
request, etc. is initiated by a device other than DMAN. Failing to
reach DMAN or detecting the signal from another device will
cause the test to fail.
To fix communication conflicts, you may need to edit the
initialization file CS4232.INI which resides in the same directory
as the other DMAN DOS applications. This is usually
C:\MIDIMAN\DMAN if you chose the default during
installation. CS4232.INI is a text file that may be edited manually
using a text editor such as DOS’s EDIT.COM or Windows’
NOTEPAD.EXE. If you change any parameters in the CS4232.INI
file you will need to run CS4232C.EXE located in that same
directory. Running CS4232C.EXE will reconfigure DMAN to the
changed settings.
IMPORTANT
: The CS4232.INI file only affects non-PnP
systems. Systems with PnP ignore the CS4232.INI file and
automatically configure the devices in the system to what it
believes are available addresses, IRQs, and DMA channels. In
this PnP case, you will have better luck modifying the settings
of the non-PnP (older ISA cards) devices to not clash with the
DMAN settings.
The following settings may be edited in the CS4232.INI file:
SndBlstr Port Address: If the SndBlstr (Sound Blaster) test fails,
you may have a port address conflict. Usually this will only
happen if another Sound Blaster compatible card is installed in
the computer. Change the SB Port Address setting indicated by
the "SbIO=" line in the [PNP] section. Set it to either 220, 230 or
240.
SndBlstr Interrupt: If the SndBlstr (Sound Blaster) test fails, you
may have an interrupt (IRQ) conflict. Change the line "WSSInt="
in the [PNP] section in the CS4232.INI file. Set it to 5,7,9,11,12 or
15.
SndBlstr DMA Channel Conflict: If the SndBlstr (Sound Blaster)
fails, you may have a DMA playback channel conflict. Change
the DMA playback channel setting in the CS4232.INI file. This is
Содержание
- Contents 1
- Fcc class b european ce compliance 3
- Fcc id imjdman 3
- Introduction 4
- What s in the box 4
- About the dman 5
- Quick start guide 5
- Digital audio features of dman 6
- About plug and play 7
- The solution 7
- About digital recording 8
- Pnp theory of operation 8
- Digital recording dos and don ts 9
- Dman connection 10
- Dman connections 12
- Hardware installation 12
- Daughterboard installation optional 14
- Driver and utilities installation 15
- Please follow these step 15
- Windows 3 x software 15
- Audio setup for non pnp computers 19
- Windows 3 x driver control panel 19
- Audio setup for computers with pnp 20
- Midi mpu401 setup 21
- Audio input control panel 22
- Windows 3 x utility applications 22
- Audio mixer control panel 24
- The audio transport 26
- Defining a new audio file 28
- The user defined audio transport button 29
- Sound check application 30
- Driver installation 31
- Windows 95 software 31
- Windows 95 driver configuration 32
- Windows 95 mixer wss mixer 33
- Click the recording button with the left mouse button to bring up the recording mixer shown are the devices that are allowed as inputs to the recording mixer again unchecking a specific box will eliminate that device from the input mixer window known as the wave input window the wave input window is accessed when the ok button is clicked 35
- Windows sound recorder 36
- Dman diagnostics utility 38
- Dos software utilities 38
- Dman dos mixer utility 39
- Dman with 3rd party applications 41
- Audio formats 42
- Disk space per minute 42
- Disk space requirements for typical recording formats 42
- Dman supports recording and playback in many audio formats when selecting an audio format you are usually trading off sound quality versus the amount of disk space the recorded audio will consume in general sound quality increases as the sample rate increases as the number of bits used increases as stereo is used instead of mono and when the audio is not compressed i e its format is pcm not adpcm or a law sample rate is the parameter most directly related to frequency response and should be chosen carefully unless you have unlimited disk space available choose a sample rate that is at least twice the frequency this is called the nyquist value of the highest audio frequencies you want to record for example if your source material has a frequency range of 30 hz to 10 khz you can record at a sample rate of 22 khz increasing to 44 khz is unlikely to improve the audio quality and it will take twice as much disk space to store the file below is a table of commonly used audio formats and the 42
- Format 42
- Hard disk space requirements for typical audio formats 42
- Sample 42
- Typical use 42
- Interrupt ibm pc assigns this interrupt to 43
- This section addresses potential problems that can occur in all operating system environments with emphasis on hardware troubleshooting within the pc environment there is a limited number of hardware resources addresses irqs and dma channels available for use since audio cards require many resources most audio card installation problems arise from improperly set irq and dma values the tables below list the irq and dma channel assignments normally used in the pc environment when you experience problems that indicate a resource conflict you can compare the irq and dma channels shown in the tables below with your current parameters as listed in the configuration screen 43
- Troubleshooting 43
- Typical irq assignments 43
- Channel 44
- Ibm pc assigns this channel to 44
- Typical dma assignments 44
- Dos troubleshooting 45
- Windows 3 x troubleshooting 47
- Windows 95 troubleshooting 49
- Appendix technical specs 51
- Board configuration 51
- Channel volume controls 51
- External audio inputs 51
- External audio outputs 51
- Limited lifetime warranty 52
Похожие устройства
- Panasonic DMC-TZ20EE-K Инструкция по эксплуатации
- HP Pavilion p6745ru LF985EA Инструкция по эксплуатации
- JVC GR-DVL108 Инструкция по эксплуатации
- Polaris PCH 2076W Инструкция по эксплуатации
- Stiebel Eltron HFA/EB 80 Z 73112 Инструкция по эксплуатации
- M-Audio DIO2448 Инструкция по эксплуатации
- Panasonic DMC-TZ18EE-K Инструкция по эксплуатации
- HP 310-1110ru XT030EA Инструкция по эксплуатации
- JVC GR-DVL107 Инструкция по эксплуатации
- Polaris PCH 1071 Инструкция по эксплуатации
- Jet DDS-237 Инструкция по эксплуатации
- M-Audio DigiPatch Инструкция по эксплуатации
- Panasonic DMC-FS35EE-K Инструкция по эксплуатации
- HP Omni 200-5310ru XT025EA Инструкция по эксплуатации
- JVC GR-DVL100 Инструкция по эксплуатации
- Panasonic AJ-SPD850 Инструкция по эксплуатации
- M-Audio Delta TDIF Инструкция по эксплуатации
- Timberk SWH RS1 100 V Инструкция по эксплуатации
- Polaris PCH 1572 Инструкция по эксплуатации
- HP LaserJet P1102w (CE657A) Инструкция по эксплуатации