Moxa ICF-1280I-S-ST [8/16] Fiber cable

Moxa ICF-1280I-M-ST [8/16] Fiber cable
- 8 -
You should also pay attention to the following:
The temperature rating of the input connection cable should be higher
than 91°C.
The cross sectional area of the ground wire should be at least 3.31
mm
2
.
The terminal block plug should be suitable for 28-12 AWG
(0.0804-3.31 mm
2
) wire and a torque of 4.5 lb-in.
Fiber Cable
ST-Port Pinouts
ST-Port to ST-Port Cable Wiring
PROFIBUS Pin Assignment
PIN
Signal Name
1
N.C.
2
N.C.
3
PROFIBUS D+
4
RTS
5
Signal common
6
5 V
7
N.C.
8
PROFIBUS D-
9
N.C.
Federal Communications Commission Statement
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including
interference that may cause undesired operation.
ATEX and IECEx Information
1. Certificate number
ATEX: DEMKO 14 ATEX 1384X
IECEx: IECEx UL 14.0094X
2. Ambient range
-40°C Tamb 75°C for models with suffix of “-T”
-10°C ≤ Tamb ≤ 60°C for models without suffix of-T”
3. Certification string:
ATEX: Ex nA nC IIC T4 Gc, Ex nA nC op is IIC T4 Gc
IECEx: Ex nA nC IIC T4 Gc
4. Standards covered
EN 60079-0:2012+A11:2013/IEC 60079-0:2011 Ed.6
EN 60079-15:2010/IEC 60079-15:2010 Ed.4
Скачать