Moxa ioLogik W5340-HSPA Технические характеристики онлайн

Moxa ioLogik W5340-HSPA Технические характеристики онлайн
1
www.moxa.com
info@moxa.com
Remote I/O
Introduction
Automatic Data Updates from SD Cards Following Network Failures
When the MX-AOPC UA Server is used in combination with the MX-
AOPC Logger, then following any network failure an ioLogik W5300
remote client will, upon reconnecting, restore to the central database
any data that was accumulated during the downtime. Following a
network failure, the MX-AOPC UA Logger will, compare received data
stored in the database with the historical data stored locally on the
W5300. If there are any gaps in the database record, the MX-AOPC
Logger will restore the missing data by requesting re-transmission
from the remote ioLogik client.
ioLogik W5300 Series
ioLogik W5300 series remote I/O modules are hardy, metal-encased
remote I/O units that combine a cellular modem, a remote I/O module,
and a data logger with cellular communications (GPRS/HSPA) suitable
for use in a wide variety of innovative I/O applications. ioLogik
W5300 devices also provide Moxa’s patented Click&Go programming
interface, giving engineers a powerful, simple tool that streamlines
installation and setup into a nearly effortless process.
The ioLogik W5300 also delivers local data logging in a storage
space expandable up to 32 GB. Thee ioLogik W5300 further comes
with Moxa’s innovative, patented MX-AOPC UA Server software, that
transforms network communications from centralized polling by the
control system to event-based notifications that originate at the edge.
By eliminating constant polling, communications may be brought up
to real time speeds while reducing hardware costs and overall network
overhead.
ioLogik W5300 devices provide benefits beyond mere cellular
connectivity and remote input/output management; they are ideal
solutions for any number of industrial applications, including:
• Pipeline monitoring for water, oil, and gas facilities
• Pump station and lift station monitoring
• Environmental monitoring
• Security and surveillance
Smart cellular remote I/O with Click&Go Logic
Using Active OPC’s push communications, SCADA can directly
communicate with cellular devices hidden behind private
IP addresses
Active communication with patented MX-AOPC UA Server and
Active OPC Server
Automatically complement disconnection period data with
DA-Center software
Patented Click&Go logic provides strong, intelligent
front-end programming options, up to 24 rules
Smart alarm management with SMS, email, SNMP traps, TCP, UDP
3-in-1 RS-232/422/485 serial port for connecting to serial devices
in the field
Up to 32 GB SDHC data logging memory
Simplify I/O management with the MXIO library for Windows or Linux
Скачать