Moxa ioLogik E2214 — настройка DIO каналов в устройствах управления [51/263]

Moxa ioLogik E2210-T [51/263] Iologik e2200 series using ioadmin
ioLogik E2200 Series Using ioAdmin
3-20
Configuring Selectable DIO Channels
Channels DIO-0 to DIO-11 support both DI and DO channel operations. When the ioLogik E2200 unit is turned
on, each DIO channel will be configured to act as either a DI or DO channel, according to the Power On
Settings. To switch between DI and DO channel operation, select the desired mode in the I/O Direction field
under Power On Settings. After clicking Apply, you will need to restart the ioLogik E2242 for the new setting
to take effect.