Moxa ioPAC 5542-C-T — настройка и конфигурация RTU: Полное руководство для пользователей [6/52]
Превью страниц
Страница 6 /
52
![Moxa ioPAC 5542-HSPA-C-T [6/52] Supported products](/views2/1201435/page6/bg6.png)
ioPAC RTU Software Introduction
1-2
Overview
This section introduces the scope of this document and lists related documents for reference.
Scope
The purpose of this document is to help users set up and configure the ioPAC RTU and become familiar with the
programming environment quickly. The following topics are covered in this document:
Introduction
Getting Started
RTU Management
RTU Communications
RTU Data Acquisition
RTU Programming
The following information is provided in the Appendix:
System Commands
Related Documents
Additional information about ioPAC RTU features is available in the following manuals, which can be found in
the ioPAC RTU Documentation & Software CD.
ioPAC 8500 RTU Hardware User’s Manual
C/C++ Sample Code Programming Guide for ioPAC RTU Controllers
Supported Products
ioPAC 8500 Series
ioPAC 5500 Series
Software Architecture
The ioPAC RTU controller uses an ARM9 based industrial grade CPU for the system and ARM Cortex™ M4 based
CPUs for the modules. It provides up to 10 MB Flash ROM, 64 MB on-board SDRAM, and a microSD socket (up
to 32 MB) for users to install application software and to store data directly on the controller.
The pre-installed operating system (OS) provides an open platform for software program development, which
follows a standard Linux-based architecture. Software that runs on desktop PCs can be easily exported to the
RTU controller with a cross compiler. Program porting can be done with the toolchain provided by Moxa.
The built-in flash ROM is partitioned into Boot Loader, Kernel, Root File System, and User directory partitions.
In order to prevent user applications from crashing the Root File System, the RTU controller uses a unique Root
File System with Protected Configuration for emergency use. This Root File System comes with serial and
Ethernet communication capability for users to load the Factory Default Image file. User settings and
applications are saved in the user directory.
To improve system reliability, the RTU controller has a built-in mechanism that prevents the system from
crashing. When the kernel boots up, the RTU will mount the root file system in read-only mode, and then enable
services and daemons. At the same time, the kernel will start searching for system configuration parameters
via rc or inittab.
Normally, the kernel uses the Root File System to boot up the system. The Root File System is protected, and
cannot be changed by users, which creates a safe zone for users.
Содержание
150- Www moxa com product
- Iopac rtu software user s manual
- First edition july 2013
- Www moxa com support
- Trademarks
- Technical support contact information
- Iopac rtu software user s manual
- Disclaimer
- Copyright notice
- Table of contents
- Introduction
- Supported products
- Software architecture
- Related documents
- Overview
- Iopac rtu software introduction
- Journaling flash file system jffs2
- Iopac rtu software introduction
- Software package
- Iopac rtu software introduction
- Getting started
- Modifying network settings with the serial console
- Iopac rtu software getting started
- Hardware and software requirements
- Development procedure
- Developing the first program
- Configuring the ethernet interface
- Modifying network settings over the network
- Iopac rtu software getting started
- Connect an rtu to a linux pc
- Install the toolchain onto the pc
- Develop code compile the program
- Set cross compiler glibc environment variables
- Root localhost telnet 192 68 27 54 trying 192 68 27 54 connected to 192 68 27 54 escape character is moxa login
- Root localhost telnet 192 68 27 54
- Root localhost path usr local arm linux bin path
- Root localhost mount dev cdrom mnt cdrom root localhost sh mnt cdrom software toolchain arm linux_vx x sh
- Root localhost cd tmp root localhost tmp mkdir example root localhost tmp cp r mnt cdrom software sample hello_world tmp example
- Root localhost cd tmp example hello_world root localhost tmp example hello_world make
- Iopac rtu software getting started
- Upload run the program
- Root moxa home chmod x hello_world root moxa home hello_world
- Root moxa df h
- Root localhost tmp example hello_world make usr local arm linux bin arm linux gcc i usr local arm linux include i usr local arm linux include rtu o hello_world hello_world o l usr local arm linux lib lpthread lmxml l usr local arm linux lib rtu lmoxa_rtu lrtu_common ltag wl rpath lib rtu wl allow shlib undefined
- Root localhost tmp example hello_world ftp 192 68 27 54
- Root localhost telnet 192 68 27 54
- Put hello_world
- Iopac rtu software getting started
- Rtu management
- Upgrading the firmware
- System information
- Iopac rtu software rtu management
- Firmware upgrade and default settings
- Attention
- Iopac rtu software rtu management
- Recovering the firmware
- Iopac rtu software rtu management
- Loading factory defaults
- Iopac rtu software rtu management
- Enabling and disabling daemons
- Iopac rtu software rtu management
- Run level settings
- Iopac rtu software rtu management
- Iopac rtu software rtu management
- System time setting
- Setting the time manually
- Updating the time with ntp client
- Updating the time automatically
- Iopac rtu software rtu management
- Ntp server setting
- Iopac rtu software rtu management
- Executing scheduled commands with cron daemon
- Software lock
- Iopac rtu software rtu management
- Rtu communications
- Modbus tcp master and slave
- Iopac rtu software rtu communications
- Internet configuration
- Enabling the telnet ftp server
- Disabling the telnet ftp server
- Telnet ftp
- Iptables
- Iopac rtu software rtu communications
- Iopac rtu software rtu communications
- Observe and erase chain rules
- Iopac rtu software rtu communications
- Examples
- Iopac rtu software rtu communications
- Examples
- Define policy for chain rules
- Append or delete rules
- Nat snat
- Iopac rtu software rtu communications
- Iopac rtu software rtu communications
- Enabling nat at bootup
- Iopac rtu software rtu communications
- Ppp dial up service
- Port forwarding dnat
- Iopac rtu software rtu communications
- Example 1 connecting to a ppp server over a simple dial up connection
- Iopac rtu software rtu communications
- How to check the connection
- Example 2 connecting to a ppp server over a hard wired link
- Setting up a machine for incoming ppp connections
- Iopac rtu software rtu communications
- Iopac rtu software rtu communications
- Setting up the iopac rtu controller as an nfs client
- Sending mail
- Openvpn
- Nfs network file system client
- Iopac rtu software rtu communications
- Example
- Setup 1 ethernet bridging for private networks on different subnets
- Iopac rtu software rtu communications
- Setup 2 ethernet bridging for private networks on the same subnet
- Iopac rtu software rtu communications
- Setup 3 routed ip
- Iopac rtu software rtu communications
- Ntp server client
- Iopac rtu software rtu communications
- Serial configuration
- Port trunking
- Modbus rtu master
- Iopac rtu software rtu communications
- Rtu data acquisition
- I o data access
- Battery backup sram
- Active opc server
- Millisecond timestamp
- Iopac rtu software rtu data acquisition
- Rtu programming
- Using c c
- Steps for installing the linux toolchain
- Programming guide
- Memory usage
- Linux toolchain
- Iopac rtu software rtu programming
- Iopac rtu software rtu programming
- Compilation for applications
- On line debugging with gdb
- Library and apis
- Iopac rtu software rtu programming
- Editor
- A system commands
- System commands
- File manager
- Process
- Network
- Moxa special utilities
- Iopac rtu software system commands
Похожие устройства
-
Moxa ioPAC 5542-HSPA-IEC-TТехнические характеристики -
Moxa ioPAC 5542-HSPA-IEC-TРуководство по аппаратной части -
Moxa ioPAC 5542-HSPA-IEC-TИнструкция по эксплуатации -
Moxa ioPAC 5542-IEC-TТехнические характеристики -
Moxa ioPAC 5542-IEC-TРуководство по аппаратной части -
Moxa ioPAC 5542-IEC-TИнструкция по эксплуатации -
Moxa ioPAC 5542-HSPA-C-TРуководство по аппаратной части -
Moxa ioPAC 5542-HSPA-C-TТехнические характеристики -
Moxa ioPAC 5542-HSPA-C-TИнструкция по эксплуатации -
Moxa ioPAC 5542-C-TРуководство по аппаратной части -
Moxa ioPAC 5542-C-TТехнические характеристики -
Moxa 85M-5401-TТехнические характеристики
Узнайте, как быстро настроить и конфигурировать RTU, включая управление, коммуникации и программирование. Полезные советы и информация для пользователей.