Moxa VPort P06-1MP-M12-CAM60-CT [42/65] Configuring snmp settings

Moxa VPort P06-1MP-M12-CAM42 [42/65] Configuring snmp settings
VPort P06-1MP-M12 System Configuration
4-20
SNMP
The VPort P06-1MP-M12 supports three SNMP protocols. The available protocols are SNMP V1, SNMP V2c, and
SNMP V3. SNMP V1 and SNMP V2c use a community string match for authentication, which means that SNMP
servers access all objects with read-only or read/write permissions using the community string public/private
(default value). SNMP V3, which requires you to select an authentication level of MD5 or SHA, is the most
secure protocol. You can also enable data encryption to enhance data security. SNMP security modes and
security levels supported by the VPort are shown in the following table. Select one of these options to
communicate between the SNMP agent and manager.
Protocol
Version
Security Mode Authentication
Type
Data
Encryption
Method
SNMP V1, V2c V1, V2c Read
Community
Community string
No Use a community string match for
authentication
V1, V2c
Write/Read
Community
Community string
No Use a community string match for
authentication
SNMP V3 No-Auth No No Use account with admin or user to access
objects
MD5 or SHA MD5 or SHA No Provides authentication based on
HMAC-MD5, or HMAC-SHA algorithms.
8-character passwords are the minimum
requirement for authentication.
MD5 or SHA MD5 or SHA Data
encryption
key
Provides authentication based on
HMAC-MD5 or HMAC-SHA algorithms, and
data encryption key. 8-character
passwords and a data encryption key are
the minimum requirements for
authentication and encryption.
Configuring SNMP Settings
The following figures indicate which SNMP parameters can be configured. A more detailed explanation of each
parameter is given below the figure.