Moxa VPort P06-1MP-M12-CAM60-CT [57/65] Cgi event

Moxa VPort P06-1MP-M12-CAM42-T [57/65] Cgi event
VPort P06-1MP-M12 System Configuration
4-35
CGI Event
The VPort can accept 5 CGI commands, which are sent from external devices, such as ioLogik series Ethernet
I/O devices, to be the event alarms.
NOTE
The VPort only can accept CGI commands that follow the VPort’s CGI command format.
CGI Event Trigger Actions
Setting Description Default
Enable CGI Event alarm
Enable or disable CGI Event alarm. Disable
Event Select the Event: 1, 2, 3, 4, 5 Disable
Send snapshot image
via E-mail
Once this VMD is triggered, the VPort will send the snapshot
images set in the Event Alarm/Basic page to the E-mail
addresses entered on the Network/ SMTP Server page.
Disabled
Send snapshot image
via FTP
Once this VMD is triggered, the VPort will send the snapshot
images set in the Event Alarm/Basic page to the FTP server,
which is configured on the Network/ FTP Server page.
Disabled
Send message via HTTP
Event Servers
Once this VMD is triggered, the VPort will send the message set
in HTTP Action Setting to the HTTP event servers, which are
configured on the Network/ HTTP Event Server page.
Disabled
HTTP Action Setting
Setting Description Default
Server 1, 2, 3, 4 Select the HTTP event server for sending the HTTP action Disable
Blank column Administrators can customize the message sent to the HTTP
event sever in this column
Blank