Switch Command for Cascaded Splitters
Serial port commands for cascaded splitters require identifying the chain of
ports to which the target device is connected. The formula for Switch Port
commands in a cascade are as follows:
Switch Command + Output Command + Port Number (at first stage) + Port
Number (at second stage) + Port Number (at third stage) + Control
For the example above, the command for switching off the Target Output Port
4 of the splitter connected to Port 3 at the second stage of the cascade, which,
in turn, is connected to output Port 4 at the first stage unit, is as follows:
sw o04-03-04 off
This cascade command format is applied to Mute Commands, page 17, Read
Info Commands, page 20, and Reset Commands, page 23. However, the
cascade commands are not applicable for the Version or EDID commands,
which are only applied to the first stage unit.
First Stage Unit
Second Stage Unit
Third Stage Unit
Target
Output
Содержание
- Rs 232 control tool user manual p.1
- Rs 232 control tool p.1
- Fcc information p.2
- Sj t 11364 2006 p.2
- Rs 232 control tool operation p.3
- Overview p.3
- Installing the rs 232 control tool p.3
- Installing net framework 2 p.3
- Before you begin p.3
- Gui main page p.8
- Switch port p.9
- The actions can also be performed by keying the command into the text box and clicking send or pressing the enter key as described below p.10
- Switch port commands p.10
- Switch command output command port number control p.10
- Sw o02 on p.10
- Sw o01 off p.10
- Possible values p.10
- For example to turn on output port 02 type the following p.10
- For example to turn off output port 01 type the following p.10
- The following table shows the possible values for the switch port commands p.10
- The available formulas for switch port commands are as follows p.10
- Value will be used p.11
- The port number command string can be skipped and the default p.11
- Switch port commands table p.11
- Note 1 each command string can be separated with a space p.11
- After commands are sent acknowledge messages are returned p.11
- Switch command for cascaded splitters p.12
- Edid mode p.13
- The following table shows the possible values for the edid commands p.14
- The actions can also be performed by keying the command into the text box and clicking send or pressing the enter key as described below p.14
- Possible values p.14
- For example to change the edid setting to auto type the following p.14
- Edid mode commands p.14
- Edid command control p.14
- Edid auto p.14
- Value will be used p.15
- The port number command string can be skipped and the default p.15
- Note 1 each command string can be separated with a space p.15
- Edid mode commands table p.15
- After commands are sent acknowledge messages are returned p.15
- The following table shows the possible values for the mute commands p.17
- Possible values p.17
- Mute o04 on p.17
- Mute o04 off p.17
- Mute commands the actions can also be performed by keying the command into the text box and clicking send or pressing the enter key as described below p.17
- Mute command output command port number control p.17
- For example to turn on the audio for output port 04 type the following p.17
- For example to mute the audio for output port 04 type the following p.17
- Note 1 each command string can be separated with a space p.18
- Mute commands table p.18
- After commands are sent acknowledge messages are returned p.18
- Value will be used p.18
- The port number command string can be skipped and the default p.18
- Read info p.19
- The following table shows the possible values for the read info commands p.20
- Read version p.20
- Read o03 video p.20
- Read info commands the actions can also be performed by keying the command into the text box and clicking send or pressing the enter key as described below p.20
- Read command output command port number control p.20
- Read command control p.20
- Possible values p.20
- For example to read the firmware version type the following p.20
- For example to display the video on off status for port 03 type the following p.20
- The port number command string can be skipped and the default p.21
- Read info commands table p.21
- Note 1 each command string can be separated with a space p.21
- After commands are sent acknowledge messages are returned p.21
- Value will be used p.21
- The following table shows the possible values for the reset commands p.23
- Reset o02 p.23
- Reset commands the actions can also be performed by keying the command into the text box and clicking send or pressing the enter key as described below p.23
- Reset command output command port number p.23
- Possible values p.23
- For example to reset port 02 back to the factory default settings type the following p.23
- Value will be used p.24
- The port number command string can be skipped and the default p.24
- Reset commands table p.24
- Note 1 each command string can be separated with a space p.24
- After commands are sent acknowledge messages are returned p.24
- Rs 232 setting p.25
Похожие устройства
-
Aten VS132Краткое руководство по установке -
Aten VS132Описание и спецификации продукта -
Aten VS102Руководство пользователя -
Aten VS98AКраткое руководство по установке -
Aten VS98AОписание и спецификации продукта -
Aten VS94AКраткое руководство по установке -
Aten VS94AОписание и спецификации продукта -
Aten VS92AОписание и спецификации продукта -
Aten VS92AКраткое руководство по установке -
Aten VS88Руководство пользователя -
Aten VS88Описание и спецификации продукта -
Aten VS84Руководство пользователя