Aten VM3404H [59/114] Grouping
![Aten VM3404H [59/114] Grouping](/views2/1211635/page59/bg3b.png)
Chapter 4. Browser Operation
49
Grouping
Group
Option Description
Grouping Click multiple icons to Group Outputs (highlighted in green) and
click
→|← to group the displays into one screen*. Use the Display
Preferences menu to select the Video Input for the group - each
Output icon in the Group will appear with the same Video Input
number and icon color (see Group, page 49).
Note: Before grouping you must set the Output port for each icon.
Ungroup
Select a group and click
←|→ to ungroup the displays.
Option Description
Group A Group (of Outputs) shares the same Video Input and displays
the video together as one large screen. A Group of Outputs:
Displays video across multiple monitors to form one screen
Icons have the same color and Video Input number.
Select a Group and use the Display Preferences menu to select
the Video Input.
To group outputs see Grouping, page 49.
Содержание
- Vm3404h vm3909h user manual p.1
- Sj t 11364 2006 p.2
- Safety p.2
- Emc information p.2
- User information p.3
- Telephone support p.3
- Online registration p.3
- User notice p.3
- Package contents p.4
- Chapter 3 front panel configuration p.5
- Chapter 1 introduction p.5
- Contents p.5
- Chapter 2 hardware setup p.5
- Chapter 4 browser operation p.6
- Chapter 5 rs 232 commands p.7
- Appendix p.8
- About this manual p.9
- This manual uses the following conventions p.10
- Product information p.10
- For information about all aten products and how they can help you connect without limits visit aten on the web or contact an aten authorized reseller visit aten on the web for a list of locations and telephone numbers p.10
- Conventions p.10
- Introduction p.11
- Chapter 1 p.11
- Overview p.11
- Features p.13
- Source devices p.15
- Requirements p.15
- Display devices p.15
- Cables p.15
- Supported web browsers are shown in the table below p.16
- Supported operating systems are shown in the table below p.16
- Source device operating systems p.16
- Browsers p.16
- Vm3404h front view p.17
- Components p.17
- Vm3404h rear view p.18
- Vm3909h front view p.19
- Vm3909h rear view p.20
- Chapter 2 p.21
- Rack mounting p.21
- Hardware setup p.21
- Grounding p.23
- Cable connection p.24
- Installation diagram p.25
- This page intentionally left blank p.26
- Overview p.27
- Front panel pushbuttons p.27
- Front panel configuration p.27
- Chapter 3 p.27
- Enter password p.28
- Port switching p.29
- Main screen p.29
- Input port selection p.29
- Output port selection p.31
- Chapter 3 front panel configuration p.33
- Vm3909h p.33
- The vm3404h vm3909h has a built in configuration utility via the front panel lcd which can be controlled by pressing the menu and front panel input pushbuttons 1 9 or 1 4 user can cycle through the menu options starting from ip setting page in the order shown in the table below p.33
- Press the menu pushbutton to switch between the main screen and lcd menu page when the menu is active the menu pushbutton s built in led lights up p.33
- Press 2 to go to the serial port setting page see serial port setting page 25 p.33
- Press 1 to go to the ip setting page see ip setting page 24 p.33
- Note the highlighted values are the default settings of the vm3404h p.33
- Menu pushbutton p.33
- Lcd menu organization p.33
- From the menu page p.33
- Ip setting p.34
- Serial port setting p.35
- Operation mode p.36
- Security mode p.40
- Save to a profile p.42
- Play stop the profile schedule p.43
- Profile pushbutton p.44
- Overview p.45
- Logging in p.45
- Chapter 4 p.45
- Browser operation p.45
- Menu bar p.46
- Main page p.46
- Profile list p.47
- Adding playing a profile p.47
- Profile list options p.49
- Profile p.49
- Play window p.49
- Clicking a profile or the play window opens a pop up menu with options p.49
- Profile scheduling is located below the profile list scheduling allows you to queue and play connection profiles in sequence for a specific amount of time p.51
- Profile scheduling p.51
- After selecting edit you will be presented with the following options p.52
- Connection profiles p.53
- Digital signage profile p.53
- Select source p.54
- Output icon p.54
- Click grid view to use an alternate method for configuring connection profiles see page 45 p.54
- Video wall profile p.56
- Number of displays bezel dimensions p.57
- Independent output p.58
- Blank output p.58
- Grouping p.59
- Display preferences p.60
- Video options p.62
- Output options p.62
- System settings p.64
- General p.66
- User account p.68
- Port name p.71
- Network p.72
- Firmware p.80
- Ir channel p.81
- Telnet operation p.83
- Configuration menu p.83
- This page intentionally left blank p.86
- Serial control protocol commands p.87
- Rs232 pin assignment p.87
- Rs 232 commands p.87
- Configuring the serial port p.87
- Chapter 5 p.87
- Verification p.88
- Sw o03 off enter p.89
- Sw i02 o05 enter p.89
- For example to switch input port 02 to output port 05 type p.89
- Command input number output number control enter p.89
- To turn off video output on port 03 type p.89
- To switch output port 04 to the next port type p.89
- The switch port command allows you to switch ports on the vm3404h vm3909h p.89
- The formula for the switch command is as follows p.89
- The following tables show the possible values for the switch port command p.89
- Switch port command p.89
- Sw o04 enter p.89
- Vm3404h vm3909h user manual p.90
- The port number can be skipped and the default value will be used p.90
- The following table lists the available switch port commands p.90
- Note 1 by default input port 01 is tied to output port 01 input port 02 is tied to output port 02 and so on until port 09 i e o01 i01 o02 i02 p.90
- Each command string can be separated with a space p.90
- Extended display identification data edid is a data that contains a display s basic information and is used to communicate with the video source p.91
- Edid port1 enter p.91
- Edid mode command p.91
- Command control enter p.91
- The formula for the edid command is as follows p.91
- The following tables show the possible values for the edid command p.91
- The following table lists the available edid commands p.91
- Note each command string can be separated with a space p.91
- For example to use the port1 edid mode type p.91
- The formula for the cec command is as follows p.93
- The following tables show the possible values for the cec command p.93
- The following table lists the available cec commands p.93
- Note each command string can be separated with a space p.93
- For example to enable the cec function on output port 1 type p.93
- Consumer electronics control cec allows interconnected hdmi devices to communicate and respond to the same remote control p.93
- Command output number control enter p.93
- Cec o01 on enter p.93
- Cec command p.93
- For example to turn scaling off for output port 02 type p.94
- Command output number address number horizontal resolution number vertical resolution number enter p.94
- To set the scaling for output port 04 to 1920x1080 60hz type p.94
- To set the scaling for all output ports to the connected display s native resolution type p.94
- The scaling command allows you to set a resolution for scaling the display connected to an output port p.94
- The formula for the scaling command is as follows p.94
- The following tables show the possible values for the scaling command p.94
- Scaling o04 1080p enter p.94
- Scaling o02 off enter p.94
- Scaling o native enter p.94
- Scaling command p.94
- Value will be used p.95
- The port number command string can be skipped and the default p.95
- The following table lists the available scaling commands p.95
- Note 1 each command string can be separated with a space p.95
- Echo on enter p.97
- Echo command p.97
- Command control enter p.97
- The formula for the echo command is as follows p.97
- The following tables show the possible values for the echo comman p.97
- The following table lists the available echo commands p.97
- The echo function updates the rs232 controller when operations are made via the front panel pushbuttons web browser or telnet the changes echo back to the rs232 controller to keep the settings in sync with the device p.97
- Note each command string can be separated with a space p.97
- For example to enable the echo feature type p.97
- Reset command p.98
- Read command p.98
- The following tables show the possible values for the baud rate command p.99
- The following table lists the available baud rate commands p.99
- The baud rate command allows you to set the rs 232 data rate for the vm3404h vm3909h to use options are 9600 19200 default 38400 and 115200 p.99
- Note each command string can be separated with a space p.99
- For example to set 38400 as the baud rate type p.99
- Command control enter p.99
- Baud rate command p.99
- Baud 38400 enter p.99
- The formula for the baud rate command is as follows p.99
- The save load profile command allows you to save and load connection profiles saving profiles will save the connections currently in use p.100
- The formula for the save load profile command is as follows p.100
- The following tables show the possible values for the save load profile commands p.100
- The following table lists the available save load profile commands p.100
- Save load profile command p.100
- Profile f 02 save enter p.100
- Note each command string can be separated with a space p.100
- For example to save the current connection configuration to profile 02 type p.100
- Command profile number control enter p.100
- The following table lists the available osd commands p.101
- Osd on enter p.101
- Osd command p.101
- Note each command string can be separated with a space p.101
- For example to enable the osd type p.101
- Command output command port number control enter p.101
- To enable or disable the on screen display osd using the following command p.101
- The following tables show the possible values for the osd command p.101
- Rs232 pin assignment p.102
- Safety instructions p.103
- General p.103
- Appendix p.103
- Rack mounting p.105
- Technical support p.106
- North america p.106
- International p.106
- Specifications p.107
- Note a cat 6a rj 45 cable is required in order to extend a signal to 70m p.108
- Limited warranty p.109
- Compatible receivers p.109
- Chapter 2 hardware setup p.111
- Chapter 1 introduction p.111
- Chapter 3 front panel configuration p.111
- Chapter 4 browser operation p.112
- Chapter 5 rs 232 commands p.113
- Appendix p.114
Похожие устройства
-
Aten VS0202Руководство пользователя -
Aten VS0202Описание и спецификации продукта -
Aten VS0202Краткое руководство по установке -
Aten VS0204Руководство пользователя -
Aten VS0204Описание и спецификации продукта -
Aten VS0204Краткое руководство по установке -
Aten VM0404HРуководство пользователя -
Aten VM0404HРуководство пользователя (RS-232 Control Tool) -
Aten VM0404HОписание и спецификации продукта -
Aten VM0404HКраткое руководство по установке -
Aten VM0808TРуководство пользователя -
Aten VM0808TРуководство пользователя (RS-232 Control Tool)