AM.PM sense f7507100, для кухни [5/26] F7775000 f7875000

AM.PM sense f7507100, для кухни [5/26] F7775000 f7875000
8 9
Operational range of the pressure in water
supply system 1,2 – 6,0 atm.(120-600 kPa)
Difference in hot and cold water pressure
may comprise +/- 10%. Recommended lift
-2,5 atm. In case of discrepancies of water
supply system parameters with indicated
values, it is necessary to install devices for
pressure relief/increase.
To avoid mechanical impurities (abrasive
2. Switch water supply system on and check
all connections for leakproofness. When
necessary do the additional tightening of the
connections.
3. Mount outer details in order of precedence
shown at the drawing (drw.2).
Drw.1.
Drw.2.
particles) ingress into the mixer it is
recommended to install lters 100-300 mk.
1. Mount mixer provided with the safety
casing as shown on the drw.1. into the place
prepared for installation. Installation depth
range (mounting tolerances) are designated
as “min” and “max”. Connect mixer to water
supply system. Remove safety casing
(drw.1.).
F7775000/F7875000
F7785000/F7885000

Содержание