Microlife 3BT0-H Инструкция по эксплуатации онлайн [6/30] 179997
![Microlife 3BT0-H Инструкция по эксплуатации онлайн [6/30] 179997](/views2/1216611/page6/bg6.png)
Содержание
- Félautomata vérnyomàsmérô 1
- Hasznâlati ûtmutatô 44 57 1
- Microlife 1
- Microlife bp 3bt0 h___________________________________ semi automatic blood pressure monitor instruction manual 1 13 1
- Semi automatic blood pressure monitor instruction manual 2
- Контроля артериального давления и пульса 9
- Полуавтоматический электронный прибор для самостоятельного 9
- Руководство по пользованию 9
- Пн ю 13
- Сю i __ i 13
- Instrukcja obsiugi 17
- Pólautomatyczny cisnieniomierz krwi 17
- Il_i fl 21
- Qh illi fi uu 21
- Félautomata vérnyomásmérõ 24
- Használati útmutató 24
- Qh ill 28
Похожие устройства
- Bosch wan 24260oe Инструкция по эксплуатации
- Bosch wan 24290oe Инструкция по эксплуатации
- Bosch wth 83000oe Инструкция по эксплуатации
- Bosch wan 28290oe Инструкция по эксплуатации
- Bosch wan 2416soe Инструкция по эксплуатации
- Bosch wan 20160oe Инструкция по эксплуатации
- Bosch wan 24060oe Инструкция по эксплуатации
- Bosch wan 20060oe Инструкция по эксплуатации
- Bosch kai90vi20r Инструкция по эксплуатации
- Bosch pcm 8 Инструкция по эксплуатации
- Bosch phd 9960 Инструкция по эксплуатации
- Bosch tka 6643 Инструкция по эксплуатации
- Bosch wrd 15-2 g 23 Инструкция по эксплуатации
- Bosch wrd 13-2 g 23 Инструкция по эксплуатации
- Bosch ixo v full Инструкция по эксплуатации
- Bosch ixo v medium Инструкция по эксплуатации
- Bosch ixo v basic Инструкция по эксплуатации
- Bosch twk 861p4ru Инструкция по эксплуатации
- Bosch twk 8617p Инструкция по эксплуатации
- Bosch twk 8611p Инструкция по эксплуатации
d After the inflation process lay down the pump ball and remain in a quiet and relaxed sitting position The measurement now proceeds on its own If no measu rement takes place and all that appears in the display is a flashing upwards pointing arrow see below under Inflate further When the instrument detects a pulse a heart symbol in the display starts to flash and a beep is heard for every heart beat 5 7 Memory displaying the last measurement The blood pressure monitor automatically stores the last measurement value By pressing the MEMORY button for at least 3 seconds the last measurement will be displayed e When the measurement has been concluded a long peep tone sounds The measured systolic and diastolic blood pressure values as well as the pulse frequency are now displayed The cuff pressure can now be quickly released by pressing the release valve at the pump ball ir Further information Measurements should not occur soon after each other since otherwise the resultswill be falsified Wait therefore for at least 1 minute in a relaxed position sitting or lying before you repeat a measurement 5 5 Inflating further If the cuff is not inflated sufficiently the measurement is broken off after a few seconds and a flashing arrow pointing upwards appears in the display It is then necessary to inflate further to at least 20 mmHg higher than the previous value The instruction to inflate further can appear several times If an error occurs during a measurement the measurement is discontinued and a corresponding error code is displayed example error no 1 6 Error messages malfunctions if the pressure is still not sufficient Attention If the cuff is inflated too far lover 300 mmHg HI appears in the display and a warning signal is sounded The cuff pressure must then be immediately released using the quick release valve at the pump ball As soon as the cuff is inflated sufficiently and the measurement is proceeding continue as described under points d e Error No ERR1 ERR 2 ERR 5 Possible cause s The systolic pressure was determined but afterwards the cuff pressure fell below 20 mmHg This situation can occur for example if the tube becomes unplugged af ter the systolic blood pressure has been measured Further possible cause No pulse has been detected The pressure dropped below 20 mmHg without a measurement taking place The Release valve was pressed during the measurement The measured readings indicated an unacceptable difference between systolic and diastolic pressures Take another reading following directions carefully Contact you doctor if you continue to get unusual readings 5 6 Discontinuing a measurement If it is necessary to interrupt a blood pressure measure ment for any reason e g the patient feels unwell press the quick release valve at the pump ball The device then immediately lowers the cuff pressure automatically 0 9