Grohe eurosmart cosmopolitan e 36331001 [6/64] Installatio

Grohe eurosmart cosmopolitan e 36327001 [6/64] Installatio
3
GB
Safety notes
Prevent danger resulting from damaged voltage
supply cables.
If damaged, the voltage supply cable must be
replaced by the manufacturer or his customer service
department or an equally qualified person.
Installation is only possible in frost-free rooms.
The plug-in voltage supply is only suitable for indoor use.
The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
The voltage supply must be separately switchable.
•Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
Operating conditions
Bluetooth
®
version 4.0. The current version of the
app required for using the system must be installed on
the control unit in advance.
The required App is available for free in the iTunes Store
(requires an Apple account) and the Google Play store
(requires a Google account), see fold-out page I.
For operation under adverse environments, in buildings /
rooms with reinforced concrete walls, steel and iron frame, or
near of obstructions (eg furniture) of metal, the Bluetooth
reception can be disturbed and interrupted.
The transceiver operates in the ISM-frequency range
(2.4GHz). The installation in the vicinity of equipment with the
same channel occupancy should be avoided.
In cases of malfunktions, turn off the source of interference
shortly.
Technical data
Fitting with switched-mode power supply:
Voltage supply: 100-240 V AC 50-60 Hz/6.75 V DC
Power consumption: 2.4 W
Fitting with battery:
Voltage supply: 6V lithium battery type CR-P2
Bluetooth
®
:
Power consumption: 1 W
Output: Bluetooth
®
- Class 2
Bluetooth
®
- version: 4.0
Bluetooth
® -
Transmission distance: about 10m
(depending on the environments)
Automatic safety shut-off: 60 s
(6 - 420 s adjustable)
Run-on time (0 - 19 s adjustable): 1 s
Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (7 - 20cm adjustable): 12cm
Type of fitting protection: IP 59K
Thermal disinfection possible.
Electrical test data
Software class A
Contamination class 2
Rated surge voltage 2500 V
Temperature of ball impact test 100 °C
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Avoid major pressure differences between hot and cold water
supply!
Installation, see fold-out page II.
Flush pipes thoroughly before and after
installation (observe EN 806)!
Open hot and cold water supply and check that
connections are watertight.
Setting temperature limiter,
see fold-out page II.
Operation and settings,
see technical product information, 99.0409.xxx /
99.0438.xxx
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s.
The indicator lamp in the sensor system illuminates in setting
mode when the detection zone of the fitting is reached by an
approaching user.
Setting mode is automatically terminated after 3 minutes..
Maintenance, see fold-out page III.
•Shut off hot and cold water supply.
•Disconnect voltage supply.
•Inspect and clean all components and replace if
necessary.
Batteries which are almost discharged are displayed
by a flashing indicator lamp in the sensor system.
Type of obstructions Interference or shielding
potential
Wood, Synthetic
material
Low
Water, Bricks, Marble Medium
Plaster, concrete,
glass, solid wood
High
Metal Very high