HansGrohe 13161400 ecostat select [7/72] Flow diagram see page 69

HansGrohe ecostat select 13141000 [7/72] Flow diagram see page 69
Spare parts (see page 70)
English
Fault Cause Remedy
Insucient water Supply pressure inadequate Check water pressure (If a pump
has been installed check to see if
the pump is working).
Filters are dirty Clean lter in front of the mixer
and on the MTC-thermo cartridge
Shower lter seal dirty Clean lter seal between shower
and hose
Crossow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
Backow preventers dirty or leak-
ing
Clean backow preventers, ex-
change if necessary
Spout temperature does not cor-
respond with temperature set
Thermostat has not been adjusted Adjust thermostat
Hot water temperature too low Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible thermo cartridge calcied Exchange thermo cartridge
Shower or spout dripping Dirt or sedimentation on valve seat,
shut-o unit damaged
Clean or exchange shut-o unit
Instantaneous heater didn’t work
with thermostat
Ecostop safety set removed. Remove Ecostop safety set
(95771000)
Flow limiter in handshower isn’t
removed
Remove ow limiter
Filters are dirty Clean the lter / exchange lter
Non return valve hasn’t moved
back
Exchange non return valves
Assembly see page 60
Flow diagram
(see page 69)
Shower
Bath tub
Cleaning (see enclosed brochure)