INSTALIMI
            
     


KARAKTERISTIKAT TEKNIKE TË APARATIT
Tipi
OTG 30 N OTG 50 N OTG 65 N OTG 80 N OTG 100 N OTG 120 N
Modeli OTG 30
SLIM
OTG 50
SLIM
OTG 65
SLIM
OTG 80
SLIM
OTG 100
SLIM
OTG 120
SLIM
Vëllimi [l]
30 50 65 80 100 120
Shtypja elementare [MPa] 0,6
Masa /i mbushur me ujë [kg] 19/49 24/74 28/93 31/111 36/136 41/161
Mbrojtja e kazanit kunr korodimit
emajluar / Mg anoda
Fuqia kyçëse [W] 2000
Tensioni i kyçjes [V~] 230
Klasa e mbrojtjes I
Shkalla e mbrojtjes IP 24
Koha e ngrohjes deri 7C
1)
[h] 1
05
1
55
2
30
3
05
3
55
4
35
Sasia e ujit të përzier te 40°C [l] 58 94 124 148 194 226
Shpenzimi energjik
2)
[kWh/24h] 0,90 0,99 1,13 1,26 1,71 1,81
1) Koha e ngrohjes së tërë vëllimit të ujëngrohësit me nxemës elektrik, te temperatura hyrëse e ujit të
ftohtë nga ujësjellsi 15°C.
2) Shpenzimi energjik te mirëmbajtja e temperaturës permanente ujit ujëngrohës 65°C dhe te temperatura
e rrethit 20°C, e matur sipas DIN 44532.