ERROR CAUSE REMEDY
Error Hardware error Switch on/off the de-
vice several times and
check if the symbol still
appears. If so please
call your dealer for
assistance.
TECHNICAL DATA
Range, without
target, m
0.05 to 50
Accuracy, mm ±1.5*
Smallest unit dis-
played
1 mm
Laser class 2
Laser type 635 nm, <1 mW
IP rating IP 54
Automatic switch off 3 minutes of inactivity
Display illumination yes
Battery life, 2 x AAA > 5000 measurements
Dimensions, mm 122×45×26
Weight 105g
Temperature range:
Storage
Operating
-25º to +70º
-10º to +50º
* In favourable conditions (good target surface properties, room
temperature).
Maximum deviation occurs under unfavorable conditions such as bright
sunlight or when measuring to poorly reecting or very rough surfaces.