Texas CW410 [11/12] Problem possible cause solution

Texas CW410 [11/12] Problem possible cause solution
11
Fejlfinding
Problem
Mulig årsag
Løsning
Pumpen kører, men pumper ikke vand
op
Luften kan ikke komme ud, fordi der
er folder på slangen
Ret slangen ud
Luftblærer i sugefoden
Vent i op til 60 sekunder indtil
pumpen har udluftet automatisk
gennem luftventilen. Afbryd eventuelt
kortvarigt for strømmen
Turbinehuset tilstoppet
Rens turbinehuset
Når pumpen starter falder
vandstanden til under laveste
sugeniveau
Sænk pumpen længere ned
Pumpen starter ikke eller stopper
pludseligt
Pumpen er overophedet, hvorfor
termosikringen har slået fra
Afbryd strømforsyningen og rens
turbinehuset. Husk at
vandtemperaturen ikke må overstige
35° C
Strømforsyningen afbrudt
Kontroller sikringer og
ledningssamlinger
Større partikler og sten har tilstoppet
sugefoden
Afbryd strømforsyningen og rens
sugefoden
Pumpen kører, men den oppumpede
vandmængde falder
Sugefoden er tilstoppet
Afbryd strømforsyningen og rens
sugefoden
Trouble Shooting
Problem
Possible cause
Solution
The pump runs but it doesn’t suck up
water.
The air cannot get out because the
hose is twisted
Straighten out the hose
Air buble in the draghead
Wait in 60 seconds until the pump has
aired automatically through the air
valve. If necessary disconnect the
power
The turbine housing is blocked
Clean the turbine housing
When the pump starts, the water level
falls below lowest suction level
Lower the pump further down
The pump does not start or stops
suddenly
The pump is overheated, therefore
the thermal cut-off has switched the
pump off
Disconnect the power supply and
clean the turbine housing. Make sure
the water temperature does not
exceed 35°C
The power supply is disconnected
Control devices and hose connections
Large particles and stones have
blocked the draghead
Disconnect the power supply and
clean the draghead
The pump runs but the pumped water
level declines
The draghead is blocked
Disconnect the power supply and
clean the draghed