Daikin FTXG50LW_RXG50L [3/16] Safety precautions
![Daikin FTXG50LW_RXG50L [3/16] Safety precautions](/views2/1251437/page3/bg3.png)
■English 1
English
Safety Precautions
• The precautions described herein are classified as WARNING and CAUTION. They both contain important
information regarding safety. Be sure to observe all precautions without fail.
• Meaning of WARNING and CAUTION notices
WARNING.....Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION......Failure to observe these instructions properly may result in property damage or personal injury, which
may be serious depending on the circumstances.
• The safety marks shown in this manual have the following meanings:
• After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate
the air conditioner and take care of it with the aid of the operation manual.
• The English text is the original instruction. Other languages are translations of the original instructions.
Be sure to follow the instructions. Be sure to establish an earth connection. Never attempt.
WARNING
• Ask your dealer or qualified personnel to carry out installation work.
Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.
• Install the air conditioner in accordance with the instructions in this installation manual.
Improper installation may result in water leakage, electric shocks or fire.
• Be sure to use only the specified accessories and parts for installation work.
Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.
• Install the air conditioner on a foundation strong enough to withstand the weight of the unit.
A foundation of insufficient strength may result in the equipment falling and causing injury.
• Electrical work must be performed in accordance with relevant local and national regulations and with instructions
in this installation manual. Be sure to use a dedicated power supply circuit only.
Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire.
• Use a cable of suitable length.
Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire.
• Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal
connections or wires.
Improper connections or securing of wires may result in abnormal heat build-up or fire.
• When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires
so that the control box lid can be securely fastened.
Improper positioning of the control box lid may result in electric shocks, fire or over heating terminals.
• If refrigerant gas leaks during installation, ventilate the area immediately.
Toxic gas may be produced if the refrigerant comes into contact with fire.
• After completing installation, check for refrigerant gas leakage.
Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater, stove or
cooker.
• When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air, and
use only the specified refrigerant (R410A).
The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the refrigerant pipes are not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal
pressure in the refrigeration cycle, which may result in equipment damage and even injury.
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury.
• Be sure to earth the air conditioner.
Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks.
• Be sure to install an earth leakage circuit breaker.
Failure to install an earth leakage circuit breaker may result in electric shocks or fire.
Содержание
- Daikin room air conditioner 1
- Installation manual 1
- Models 1
- Daikin industries czech republic s r o 2
- En60335 2 4 2
- Ftxg20lv1bw ftxg25lv1bw ftxg35lv1bw ftxg50lv1bw ftxg20lv1bs ftxg25lv1bs ftxg35lv1bs ftxg50lv1bs 2
- Low voltage 2006 95 ec machinery 2006 42 ec electromagnetic compatibility 2004 108 ec 2
- P290872 14n 2
- Takayuki fujii managing director pilsen 1st of jan 2014 2
- English 1 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Choosing an installation site 4
- Indoor unit 4
- Safety precautions 4
- Wireless remote controller 4
- Caution 5
- English 3 5
- Indoor unit installation drawings 5
- Intelligent eye sensor 5
- Installation tips 6
- Removing and installing the front grille 6
- Removing and installing the upper front panel 6
- Caution 7
- How to set the different addresses 7
- Installation tips 7
- When connecting to an ha system wired remote controller central remote controller etc 7
- Flaring the pipe end 8
- Installation tips 8
- Refrigerant piping work 8
- Warning 8
- Caution 9
- Refrigerant piping 9
- Refrigerant piping work 9
- Boring a wall hole and installing wall embedded pipe 10
- Indoor unit installation 10
- Installing the mounting plate 10
- Inter unit wiring 10
- Attach the drain hose to the underside of the refrigerant pipes with adhesive vinyl tape 2 wrap the inter unit wire refrigerant pipes and drain hose together with insulation tape 11
- Attachment on the right side factory default attachment on the left side 11
- Drain hose attachment position 11
- Front side of unit 11
- How to replace the drain plug and drain hose 11
- How to set drain plug 11
- Indoor unit installation 11
- Laying piping hoses and wiring 11
- Pass the inter unit wire drain hose and refrigerant pipes through the wall hole then set the indoor unit on the mounting plate hooks by using the markings at the top of the indoor unit as a guide 11
- Replace the drain plug and drain hose 2 attach the drain hose to the underside of the refrigerant pipes with adhesive vinyl tape 3 be sure to connect the drain hose to the drain port in place of a drain plug 11
- Shape the refrigerant pipe along the pipe path marking on the mounting plate 5 pass drain hose and refrigerant pipes through the wall hole then set the indoor unit on mounting plate hooks using the markings at the top of indoor unit as a guide 6 pull in the inter unit wire 7 connect the inter unit pipes 8 wrap the refrigerant pipes and drain hose together with insulation tape as shown in the figure on the right in case of setting the drain hose through the back of the indoor unit 11
- The recommended installation method is back piping when performing bottom piping or side piping refer to 5 bottom or side piping on page 10 11
- Bottom or side piping 12
- Indoor unit installation 12
- Caution 13
- Firmly fix the wires with the terminal screws 13
- Firmly fix the wires with the terminal screws outdoor unit 13
- Firmly secure wire retainer so that wires sustain no external stress 13
- Indoor unit 13
- Indoor unit installation 13
- Inter unit wire 4 core 1 m 13
- Or more h05rn 13
- Shape wires so that the service lid will fit securely 13
- Terminal block electrical component box 13
- Warning 13
- Wire retainer use the specified wire type 13
- Wiring 13
- Drain piping 14
- Indoor unit installation 14
- Test items 15
- Trial operation and testing 15
- Trial operation from remote controller 15
Похожие устройства
- LG MW25W95DIH Руководство пользователя
- Daikin FTXJ20MW_RXJ20M Инструкция по эксплуатации
- Daikin FTXJ20MW_RXJ20M Инструкция по монтажу (внутр. блок)
- Daikin FTXJ25MW_RXJ25M Инструкция по эксплуатации
- Daikin FTXJ25MW_RXJ25M Инструкция по монтажу (внутр. блок)
- Daikin FTXJ35MW_RXJ35M Инструкция по эксплуатации
- Daikin FTXJ35MW_RXJ35M Инструкция по монтажу (внутр. блок)
- Daikin FTXJ50MW_RXJ50M Инструкция по эксплуатации
- Daikin FTXJ50MW_RXJ50M Инструкция по монтажу (внутр. блок)
- Daikin FTXS20K_RXS20L3 Инструкция по эксплуатации
- Daikin FTXS20K_RXS20L3 Инструкция по монтажу (нар. блок)
- Daikin FTXS20K_RXS20L3 Инструкция по монтажу (внутр. блок)
- LG MW25W35GIH Руководство пользователя
- Daikin FTXS25K_RXS25L3 Инструкция по эксплуатации
- Daikin FTXS25K_RXS25L3 Инструкция по монтажу (нар. блок)
- Daikin FTXS25K_RXS25L3 Инструкция по монтажу (внутр. блок)
- LG MW25R35GISW Руководство пользователя
- Daikin FTXS35K_RXS35L3 Инструкция по эксплуатации
- Daikin FTXS35K_RXS35L3 Инструкция по монтажу (нар. блок)
- Daikin FTXS35K_RXS35L3 Инструкция по монтажу (внутр. блок)