Daikin FBQ100D_RZQSG100L9V [47/52] Technical data

Daikin FBQ100D_RZQSG100L9V [47/52] Technical data
12Technicaldata
Installerreferenceguide
47
RZQG71~140L_V1+Y1+RZQSG100~140L_V1+Y1
Splitsystemairconditioners
4P3855221–2014.08
RZQSG100_V1 RZQSG125_V1 RZQSG140_V1
Liquid Quantity 1
Type Flareconnection
Diameter(OD) Ø9.52mm
Gas Quantity 1
Type Flareconnection
Diameter(OD) Ø15.9mm
Drain Quantity 5
Type Hole
Diameter(OD) Ø26mm
Pipinglength Minimum 5m
Maximum 50m
Equivalent 70m
Chargeless 30m
Additionalrefrigerantcharge See"Todeterminetheadditionalrefrigerantamount"
Maximumheightdifferencebetweenoutdoor
unitandindoorunit
30m
Maximuminterunitleveldifference 0.5m
Heatinsulation Bothliquidandgaspipes
Defrostmethod Reversecycle
Defrostcontrol Sensorforoutdoorheatexchangertemperature
Capacitycontrolmethod Invertercontrolled
Capacitycontrol
Cooling Minimum
Maximum
Heating Minimum
Maximum
Safetydevices Highpressureswitch/lowpressureswitch/fandriveroverloadprotector/fuse
Standardaccessories 1installationmanual/2tiewraps
Electricalspecifications:RZQSG_V1
RZQSG100_V1 RZQSG125_V1 RZQSG140_V1
Powersupply
Name V1
Phase 1~
Frequency 50Hz
Voltage 220240V
Voltagerange Minimum 198V
Maximum 264V
Current
Nominalrunningcurrent
Startingcurrent
Z
max
CompliestoEN61000311
MinimumS
sc
value EquipmentcomplyingwithEN61000312
(a)
Maximumrunningcurrent
Recommendedfuses 40A
Wiringconnections
Forpowersupply See"Connectingtheelectricalwiring"
Forconnectionwithindoor
Powersupplyintake Outdoorunitonly
(a) European/InternationalTechnicalStandardsettingthelimitsforharmoniccurrentsproducedbyequipmentconnectedtopubliclowvoltage
systemswithinputcurrent>16Aand≤75Aperphase.